D5: Torque Control; D6: Field Weakening And Field Forcing - YASKAWA AC Drive-A1000 Technical Manual

High performance vector control drive
Table of Contents

Advertisement

B.6 d: References
u

d5: Torque Control

OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
No.
(Addr.
Name
Hex)
d5-01
Torque Control Selection
(29A)
d5-02
Torque Reference Delay
(29B)
Time
d5-03
Speed Limit Selection
(29C)
d5-04
Speed Limit
(29D)
d5-05
Speed Limit Bias
(29E)
d5-06
Speed/Torque Control
(29F)
Switchover Time
d5-08
Unidirectional Speed Limit
(2B5)
Bias
u

d6: Field Weakening and Field Forcing

No.
(Addr
Name
Hex.)
d6-01
Field Weakening Level
(2A0)
d6-02
Field Weakening Frequency
(2A1)
Limit
400
PM motor control modes are not available on 600 V class drives, CIMR-Ao5oooooooo.
V/f
V/f w PG
OLV/PM
AOLV/PM
0: Speed Control
1: Torque Control
Set to 0 when using a digital input to switch between Speed and Torque Control
(H1-oo = 71).
V/f
V/f w PG
OLV/PM
AOLV/PM
Sets a delay time for the torque reference signal. Used to suppress effects by
noisy or fluctuating torque reference signals.
V/f
V/f w PG
OLV/PM
AOLV/PM
1: Limit set by the frequency reference in b1-01.
2: Limit set by d5-04.
V/f
V/f w PG
OLV/PM
AOLV/PM
Sets the speed limit during Torque Control as a percentage of the maximum
output frequency. Enabled when d5-03 = 2. A negative setting set a limit in
the opposite direction of the Run command.
V/f
V/f w PG
OLV/PM
AOLV/PM
Sets the speed limit bias as a percentage of the maximum output frequency.
The bias is applied to the specified speed limit and can adjust the margin for
the speed limit.
V/f
V/f w PG
OLV/PM
AOLV/PM
Sets the delay time for switching between Speed and Torque Control using an
input terminal (H1-oo = 71). Reference values are held during this switch
delay time.
V/f
V/f w PG
OLV/PM
AOLV/PM
0: Disabled
1: Enabled
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
AOLV/PM
Sets the drive output voltage for the Field Weakening function as a percentage
of the maximum output voltage.
Enabled when a multi-function input is set for Field Weakening (H1-oo =
63).
V/f
V/f
V/f w PG
V/f w PG
OLV/PM
AOLV/PM
Sets the lower limit of the frequency range where Field Weakening control is
valid.
The Field Weakening command is valid only at frequencies above this setting
and only when the output frequency matches the frequency reference (speed
agree).
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Description
OLV
CLV
CLV/PM
OLV
CLV
CLV/PM
Values
Page
Default: 0
181
Range: 0, 1
Default: 0 ms
Min.: 0
181
Max.: 1000
Default: 1
181
Range: 1, 2
Default: 0%
Min.: -120
182
Max.: 120
Default: 10%
Min.: 0
182
Max.: 120
Default: 0 ms
Min.: 0
182
Max.: 1000
Default: 1
182
Range: 0, 1
Values
Page
Default: 80%
Min.: 0
182
Max.: 100
Default: 0.0 Hz
Min.: 0.0
182
Max.: 400.0

Hide quick links: