YASKAWA AC Drive-A1000 Technical Manual page 297

High performance vector control drive
Table of Contents

Advertisement

Digital Operator
Display
Overspeed
oS
(for Control Mode with PG)
ov
Overvoltage
PF
Input Phase Loss
PG Disconnect
PGo
(for Control Mode with PG)
PG Hardware Fault
PGoH
(when using PG-X3)
rF
Braking Resistor Fault
rH
Dynamic Braking Resistor
rr
Dynamic Braking Transistor
SEr
Too Many Speed Search Restarts
<1> Displayed as
when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
.
<2> Displayed as
when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
.
n
Minor Faults and Alarms
Refer to
Table 6.10
for an overview of possible alarm codes. Conditions such as overvoltages can trip faults and alarms. It is
important to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects an alarm, the ALM indicator LED blinks and the alarm code display flashes. Most alarms trigger a
digital output programmed for alarm output (H2-oo = 10). A fault (not an alarm) is present if the ALM LED lights without
blinking.
Refer to Faults on page 296
Digital Operator
Display
SI-T Station Number Setting
AEr
Error (CC-Link, CANopen,
MECHATROLINK-II)
bb
Drive Baseblock
Braking Transistor Overload
boL
Fault
Option Card Communications
bUS
Error
Serial Communication
CALL
Transmission Error
MEMOBUS/Modbus
CE
Communication Error
CrST
Cannot Reset
Excessive Speed Deviation
dEv
(for Control Mode with PG)
dnE
Drive Disabled
dWAL DriveWorksEZ Alarm
E5
SI-T3 Watchdog Timer Error
EF
Run Command Input Error
EF0
Option Card External Fault
to
EF1 to
External Fault
EF8
(input terminal S1 to S8)
FbH
Excessive PID Feedback
FbL
PID Feedback Loss
Hbb
Safe Disable Signal Input
HbbF Safe Disable Signal Input
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
Name
for information on fault codes.
Table 6.10 Minor Fault and Alarm Displays
Minor Fault
Output
Name
(H2-oo =
10)
YES
No output
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
<2>
YES
<2>
YES
Digital Operator
Page
Display
STo
311
SvE
311
UL3
312
UL4
312
UL5
Uv1
312
Uv2
313
Uv3
313
voF
313
313
Digital Operator
Page
Display
HCA
Current Alarm
316
LT-1
Cooling Fan Maintenance Time
316
LT-2
Capacitor Maintenance Time
316
Soft Charge Bypass Relay
LT-3
316
Maintenance Time
316
LT-4
IGBT Maintenance Time (50%)
oH
Heatsink Overheat
317
oH2
Drive Overheat
317
oH3
Motor Overheat
317
oL3
Overtorque 1
oL4
Overtorque 2
317
Mechanical Weakening
303
oL5
Detection 1
303
Overspeed
oS
318
(for Control Mode with PG)
318
ov
Overvoltage
MEMOBUS/Modbus Test Mode
318
PASS
Complete
318
PG Disconnect
PGo
(for Control Mode with PG)
319
PG Hardware Fault
PGoH
319
(when using PG-X3)
319
6.3 Drive Alarms, Faults, and Errors
Name
Pull-Out Detection
Zero-Servo Fault
Undertorque Detection 1
Undertorque Detection 2
Mechanical Weakening Detection 2
Undervoltage
Control Power Supply Undervoltage
Soft Charge Circuit Fault
Output Voltage Detection Fault
Minor Fault
Name
No output
No output
No output
No output
No output
Page
313
314
314
314
314
314
315
315
315
Output
Page
(H2-oo =
10)
YES
319
319
<1>
320
<1>
320
<1>
320
<1>
YES
320
YES
320
6
YES
320
YES
321
YES
321
YES
321
YES
321
YES
321
322
YES
322
YES
322
297

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents