E7: Connection Error; E8: Elevator Error - MyBinding DC-545HC Service Manual

Duplo docu cutter
Table of Contents

Advertisement

(14) E7: CONNECTION ERROR

Pro-
Cause/Defective part
ce-
dure
1
Connector
2
Feed PCB unit

(15) E8: ELEVATOR ERROR

Pro-
Cause/Defective part
ce-
dure
1
Elevator upper/
lower/switch
2
Elevator motor
3
Feed tray
4
Feed PCB unit
5
Items to be checked
Is the * displayed on the upper
right edge of the LCD?
(Indicates that AF-100 and DC-
545 are connected.)
Is the trouble cleared by
replacing the feed PCB unit?
Items to be checked
Is it normal when checked in
HELP mode (H-08)?
Does the feed tray go up and
down when checked in HELP
mode (H-29)?
Are the chain and pulley
normal?
Is the voltage measured with a
tester between CN2-5 and
CN2-6 on the feed PCB unit
+24 V (DC) while the elevator
motor is operating?
Is the trouble cleared by
replacing the feed PCB unit?
131
Chap.6
Result
Countermeasure
No
Firmly connect the AF-100 and the
DC-545.
Yes
Finish
No
Replace the main PWB unit.
Result
Countermeasure
No
Replace the faulty switch.
Yes
Go to procedure 5.
No
Adjust any malfunctions.
Yes
Replace the elevator motor.
Yes
Finish
No
Replace the main PWB unit.
HELP mode H-08 \ see p.143
HELP mode H-29 \ see p.148
z Troubleshooting Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC-545HC and is the answer not in the manual?

Table of Contents