Quantum Data 802BT User Manual page 727

Video test generator
Hide thumbs Also See for 802BT:
Table of Contents

Advertisement

2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
802BT/802R Video Test Generator User Guide
Vertical pulse too large for interlaced format
The vertical sync pulse width combined with the number of pre and post-equalization
pulses for an interlaced format is greater than the maximum supported by the generator
hardware configuration.
Incompatible analog composite sync & digital composite sync types
The generator hardware configuration does not support the video format outputting both
analog composite sync and digital composite sync type selections at the same time.
Incompatible analog composite sync & digital separate sync types
The generator hardware configuration does not support the video format outputting both
analog composite sync and digital separate sync type selections at the same time.
Analog composite sync type not compatible with analog video type
The generator hardware configuration does not support the video format's analog
composite sync type being added to the current analog video type.
ACS available on green only
The generator hardware configuration supports adding analog composite sync to only the
green analog video output
Sync type selection incompatible with analog video type selection
The video format's analog video type selection requires the use of analog composite sync.
Invalid analog composite sync type
The current firmware does not support the format's analog composite sync type parameter
value (ASCT setting) or the generator hardware configuration does not support a video
format's analog composite sync type for non-interlaced operation.
Invalid digital composite sync type
The current firmware does not support the format's digital composite sync type parameter
value (DSCT setting) or the generator hardware configuration does not support a video
format's digital composite sync type for non-interlaced operation.
Invalid digital separate sync type
The current firmware or generator hardware configuration does not support the format's
digital separate sync type parameter value (DSST setting)
Invalid sync type selection
The current firmware does not support the format's active sync type selection (SSST
setting).
717

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

802r

Table of Contents