Quantum Data 802BT User Manual page 252

Video test generator
Hide thumbs Also See for 802BT:
Table of Contents

Advertisement

AVPS
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
242
Appendix A Command Reference
Analog Video Pedestal Swing
Format parameter setting - Analog video signal
Sets a black pedestal level between the blanking level (0.0 I.R.E.) and the peak video
level (100.0 I.R.E.). The AVPS? query returns the current setting of AVPS.
AVPS level
level
min = 0.0 I.R.E.
max = 100.0 I.R.E.
AVPS?
level
AVPG
must be set to ON to enable the use of the pedestal. The
the generator to use the new setting. The
setting and redraws the test image.
Example
AVPG 1
// Enable use of a black level pedestal
AVPS 7.5
// Set pedestal level to 7.5 IRE
FMTU
// Update hardware to current buffer contents
FMTU
ALLU
command updates hardware to the new
command instructs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

802r

Table of Contents