Special Sync Probe Pulse
Determines what lines in the frame or field the probe pulse occurs on the special sync
output. The PSPM? query returns the current PSPM value.
PSPM mode
mode integer
0 = once per frame
1 = every active line in frame
3 = every line in frame
PSPM?
0, 1, or 3
The
FMTU
command instructs the generator to use the new settings. The
updates the hardware to the new settings and redraws the test image.
PSPG, PSPP, PSPW, PSHD,
PSPG 1
// Enables probe pulse on special sync
PSPP 1
// Sets probe pulse polarity to positive
PSPW 10
// Sets probe pulse width to 10 pixels
PSHD 200
// Sets probe pulse horizontal delay to 200 pixels
PSVD 300
// Sets probe pulse vertical delay to 300 pixels
PSPM 1
// Sets probe pulse to occur on each active line in a frame
ALLU
// Applies the settings
PSVD