Quantum Data 802BT User Manual page 388

Video test generator
Hide thumbs Also See for 802BT:
Table of Contents

Advertisement

HVSA
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
Example
378
Appendix A Command Reference
Horizontal Vertical Sync Adjustment
Format parameter setting - Synchronization
Lengthens the serration period a given number of pixels from the format's nominal default
value as required by certain military STANAG video formats. The HVSA? query returns the
current setting of HVSA.
HVSA pixels
pixels
integer, 0 and less than HSPW
HVSA?
pixels
The
FMTU
command instructs the generator to use the new settings. The
updates the hardware to the new settings and redraws the test image.
HVSA 30;
ALLU
ALLU
command