Quantum Data 606 Quick Start Manual

Video test generators

Advertisement

Quick Links

Table of Contents

M
606, 607, 608, 609
ODEL
Video Test Generators
Quick Start Guide
attery Information and Installation ............................................... 2
Making Connections ...................................................................... 3
Front Panel Controls and Indicators .............................................. 4
Selecting Video Formats ............................................................... 5
Selecting Test Images ................................................................... 6
Video and Sync Outputs Gating .................................................... 6
Options Menu ................................................................................ 7
Power Save Control ...................................................................... 7
Resetting Formats List to Factory Default ..................................... 7
Outputs Calibration Procedure ...................................................... 8
Learning a Monitor's EDID DDC Data .......................................... 11
Test Menu .................................................................................... 12
Test Sequence Mode .................................................................. 12
Burn-In Test Mode ....................................................................... 13
Horizontal Frequency Shift Test .................................................. 13
DDC Step Mode .......................................................................... 14
Taking CS-1 Color Sensor Measurements .................................. 14
Audio Menu ................................................................................. 15
Installing New Firmware .............................................................. 15
VGM Software Overview and Basic Operation ........................... 16
Creating Formats Using VGM Software ...................................... 17
Creating Sequences Using VGM Software ................................. 18
Specifications Summary .............................................................. 19
Service and Support Locations ................................................... 20
Declaration of Conformity ............................................................ 20
Part 68-00189 Rev I
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 606 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Quantum Data 606

  • Page 1: Table Of Contents

    Table of Contents 606, 607, 608, 609 ODEL Video Test Generators Quick Start Guide attery Information and Installation ..........2 Making Connections ..............3 Front Panel Controls and Indicators ..........4 Selecting Video Formats ............... 5 Selecting Test Images ..............6 Video and Sync Outputs Gating ............
  • Page 2: B Attery Information And Installation

    Preparation for first time use Battery Types Used The Model 606, 607, 608 and 609 generators come with four (4) size AA rechargeable Nickel Metal Hydride (NiMH) batteries. These 1500 mA-H rated batteries can normally be recharged about 1000 times before needing replacement. Only suitable NiMH batteries can be safely recharged in the generator.
  • Page 3: Making Connections

    Making Connections Test Signal Output Connectors S-Video Receptacle VGA Receptacle 4 Pin mini-DIN (Not on 606) (No HDTV Y,Pr,Pb on 606*) 15 Pin HD D-Sub Chrominance (C) Luminance (Y) Pin # Signal Ground Ground Red Video (*HDTV Pr) NTSC / PAL...
  • Page 4: Front Panel Controls And Indicators

    Obtain EDID data from seconds after any button format types are generator’s unit under test via DDC press on batteries. Stays on shown by FORMAT configuration connection. button options. when using external power Page 4 Model 606, 607, 608, 609 Quick Start Guide...
  • Page 5: Selecting Video Formats

    Use +/- buttons to page through list when more than 8 items of a given type are available. You can use the Quantum Data VGM software package to add your own formats.You can also edit or replace any of the factory default formats.
  • Page 6: Selecting Test Images

    O U T * Component Composite Sync ON/OFF DSS - Select Digital Blue Color Separate (H&V) Sync Component Current Current ON/OFF OUT - All test signal Video Format Test Image outputs ON/OFF Page 6 Model 606, 607, 608, 609 Quick Start Guide...
  • Page 7: Options Menu

    NTSC_Cal - (Not on Model 606) Displays calibration Menu for setting peak white signal on the TV output BNC connector. Appears only if the generator has been configured to allow recalibration (see page 8).
  • Page 8: Outputs Calibration Procedure

    Options Menu - Output Calibration All Model 606, 607 and 608 video test generators use programmable hardware to set all of the ampli- tude calibration factors analog video outputs. These calibration factors are stored in Flash EPROM and are not lost if the batteries are run down or removed. Firmware updates will not affect these factors in most cases.
  • Page 9 Options Menu - Output Calibration Continued Setting calibration factors to nominal values The Reset selection in the main calibration menu (top figure on right) sets all of the generator’s calibration factors to default nominal values. You _ _ _ _ _ C a l i b r a t e B l a c k _ _ _ _ _ _ _ _...
  • Page 10 17) This completes the calibration adjustments for a Model 606 generator. Skip steps 18 through 28 for the Model 606 and continue with step 29. 18) Select BP_Sync and then use the BP_Sync+ and -BP_Sync menu buttons to set the DC level to 600 mV +/- 3 mV.
  • Page 11: Learning A Monitor's Edid Ddc Data

    Learn Monitor Function (DDC/EDID Data) Learn Monitor LEARN MONITOR Reads back EDID data from a _ _ _ _ _ _ _ R e a d i n g _ _ _ _ _ _ _ M o n i t o r VESA®...
  • Page 12: Test Menu

    The current firmware includes a sample test sequence. You can use Quantum Data’s VGM software to create and save your own test sequence. Use the Burn-in Test menu selec- tion if you wish for the generator to automatically cycle through all of the steps.
  • Page 13: Burn-In Test Mode

    The current firmware includes a sample burn-in sequence. Future versions of generator firmware and Quantum Data’s VGM software may permit user defined burn-in sequences to be created and downloaded into the generator.
  • Page 14: Ddc Step Mode

    Video) CS-1 Probe Test Mode TEST Uses the Quantum Data Model CS-1 color sensor to measure the chromaticity and luminance (brightness) of the test CRT display. The CS-1 probe connects CS1 Probe directly to the serial port on the generator. Chromaticity is shown as x,y C.I.E.
  • Page 15: Audio Menu

    Audio Mode Sub-menu and Installing Firmware Audio Menu A u d i o Audio menu buttons indepen- A u d i o O f f TEST dently toggle stereo audio output channels on and off (Models 608 and 609 only). Audio Left channel is also as the monophonic audio source for the modulated RF output on the Model 609.
  • Page 16: Vgm Software Overview And Basic Operation

    Operating with VGM Software Current Capabilities The current firmware in the Model 606, 607 and 608 generators allows you add and delete video formats and test sequences that are stored in the generator’s non-volatile memory. About 120 formats and one test sequence can be stored with the current firmware. The easiest way to create and edit formats and sequences is to use Version 3.00 of Quantum...
  • Page 17: Creating Formats Using Vgm Software

    Programming Video Formats with VGM Software Selecting a Format to Edit 1) You can either choose to start with a default format in the VGM format editor or choose any of the formats available in the generator. Refer to the VGM help file for information on using the VGM’s default format.
  • Page 18: Creating Sequences Using Vgm Software

    Sequence. Only one Sequence can be stored in the generator at any given time. You will get a warning if you start to save a Sequence using the same name as the currently stored Sequence. Page 18 Model 606, 607, 608, 609 Quick Start Guide...
  • Page 19: Specifications Summary

    PAL (607, 608, 609) through supported standard formats. HDTV (608, 609) Channels: UHF channels with Battery Power Operation Edit Method: Quantum Data’s MS-Windows frequencies per NTSC (M) based VGM software and PAL (G). Specific channel Type: Four AA batteries installed usage/availability determined internally.
  • Page 20: Service And Support Locations

    Use of premium quality shielded cables is required for electromagnetic compatibility. version: 2.02. "Model 606, 607, 608, 609 When and Where Issued Marks of Compliance Quick Start Guide" 07-September-2001 Part# 68-00189 Romeoville, IL; USA Rev. I (15-May-2003) Page 20 Model 606, 607, 608, 609 Quick Start Guide...

This manual is also suitable for:

607609608

Table of Contents