RGBW
Class
Description
Command syntax
Related commands
Example
Video Test Generator User Guide
RGB Write
LUT Management
Writes RGB levels to the slot location specified within the current lookup table buffer when
a lookup table editing session is active, and writes the levels directly to the LUT hardware
when a lookup table editing session is not active.
RGBW slot red_level green_level blue_level
slot integer
0 to 15 when PELD = 4
0 to 255 when PELD = 8
red_level, green_level, blue_level integer
min = 0
max = LMAX setting (255 nominal)
RGBQ?
LUTE;RGBW 1 255 128 0
// Set slot 1 to an orange color