PCPG
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
Example
464
Appendix A Command Reference
Pixel Clock Pulse Gate
Format parameter settings
Enables and disables the pixel clock pulse output on generators that have a pixel clock
output available. The PCPG? query returns the current setting of PCPG.
PCPG mode
mode
0 = OFF
1 = ON
PCPG?
mode
FMTU
or
ALLU
PCPG 1
// Enable pixel clk output in buffer
FMTU
// Update hardware with format data