PSPW
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
Related commands
Example
490
Appendix A Command Reference
Probe Sync Pulse Width
Special Sync Probe Pulse
Sets the width in pixels of the probe pulse on the special sync output. The PSPW? query
returns the current PSPW value.
PSPW width
width integer
1 pixel to (HTOT - 1))
PSPW?
width
The
FMTU
command instructs the generator to use the new settings. The
updates the hardware to the new settings and redraws the test image.
PSPG, PSPP, PSHD, PSVD,
PSPG 1
// Enables probe pulse on special sync
PSPP 1
// Sets probe pulse polarity to positive
PSPW 100
// Sets probe pulse width to 100 pixels
ALLU
// Applies the settings
PSPM
ALLU