DNUM
Class
Description
Command syntax
Query syntax
Query response
Example
Video Test Generator User Guide
Display sequence step NUMbers
Sequence editor commands
Enables and disables the addition of the sequence step number to the displayed test
image when running a sequence.
DNUM mode
mode
0, 1 or 2
DNUM?
mode
DNUM 1
// Enable the displaying of the sequence step #