Quantum Data 802BT User Manual page 338

Video test generator
Hide thumbs Also See for 802BT:
Table of Contents

Advertisement

FMTJ
Class
Description
Command syntax
Other required
commands
Example
328
Appendix A Command Reference
ForMaT Justify
Format memory management
Corrects some types of timing errors for the current data in the format buffer. The following
errors are corrected:
Pixel Rate errors 2071 and 2072
Video Memory Size error 2550
Horizontal Blanking errors 2140, 2141, 2150 and 2155
Horizontal Total errors 2090 and 2091
Horizontal Sync Pulse Width errors 2181 and 2201
The justification routine tries to keep the format close to your original specifications.
However, the format should be reviewed after it is justified to make sure it still meets your
timing requirements.
FMTJ
The
FMTU
command instructs the generator to use the new settings. The
updates hardware to the new settings and redraws the test image. The
be used to see if any errors remain.
FMTJ
FMTU
// Update hardware to current buffer contents
ALLU
command
FMTG?
query can