Basic Procedure

4.5.4 Settings of FP7 MC Unit

To enable the limit function, the axis parameter "Limit input" in CMI should be set to be
enabled. Also, the input logic should be confirmed on CMI.
 Settings related to Limit switch
Parameter name
Limit switch
Limit switch
connection
Limit + Switch logic
Limit - Switch logic
KEY POINTS
In the system using FP7 MC Unit, limit switches are connected to the
general-purpose inputs (SI-MON3 and SI-MON4) of Servo Amplifier A5B.
When the "Limit switch" is set to "Enabled" in the above parameter, the
state of the general-purpose inputs (SI-MON3 and SI-MON4) of Servo
Amplifier A5B is reflected as the limit inputs of FP7 MC Unit.
It is recommended to select "Normal Open (A contact)" for "Limit + Switch
logic" and "Limit - Switch logic". The input logic selected on the servo
amplifier A5B is reflected as is.
REFERENCE
For details of the axis parameter settings, refer to "5.2 Axis Parameter
Setting".
4-24
Default
Description
When using the limit switch function or the home return function
N: Disabled
using limit switches, select "A: Enabled".
N: Disabled, A: Enabled
When the arrangement of the connected "limit switch +" and "limit
switch -" is opposite to the input state loaded to the unit, select "R:
S: Standard
Reverse connection".
S: Standard, R: Reverse connection
1: Normal Close
Select the input logic of the limit swtiches.
(B contact)
0: Normal Open (A contact), 1: Normal Close (B contact)