Basic Procedure

4.2.2 Download of I/O map

The created I/O map is downloaded to the CPU unit as part of configuration information.
Perform the following operations on FPWIN GR7.
 Download to the CPU unit
The I/O map is saved in the CPU unit together with program data. Execute "Online" >
"Download to PLC".

4.2.3 Storage of I/O map

The created I/O map is saved as project data as part of configuration information. Perform the
following operations on FPWIN GR7.
 Save as files
• To save the I/O map as "Entire project", execute "Project" > "Save As".
• To save only the "I/O map setting" information, press the "Save Setting" button in the "I/O
map" setting dialog box.

4.2.4 Confirmation of I/O Allocation

• I/O numbers allocated to the unit are decided by registering them in the I/O map.
• I/O numbers vary depending on the starting word number registered for the slot where the
unit is installed.
Example) When the starting word number is 10, the "link establishment flag" of FP7 MC Unit
is X100, and "system stop request signal" is Y100.
REFERENCE
For details, refer to "15.2 I/O Allocation".