Precautions On Programming; Turning Off Power Supply Clears Contents In Unit Memories; Operation Cannot Be Switched Once One Operation Has Started; Operation When Plc Mode Changes From Run To Prog - Panasonic AFP7MC16EC User Manual

Motion control unit
Hide thumbs Also See for AFP7MC16EC:
Table of Contents

Advertisement

Creation of User Programs

7.3 Precautions On Programming

7.3.1 Turning Off Power Supply Clears Contents in Unit Memories

• Data in unit memories are cleared when the power is turned off.
• When the powe is turned on again, data is preset in the parameters saved in the FROM
within FP7 MC Unit.

7.3.2 Operation Cannot be Switched Once One Operation Has Started

• If any of the startup requests for position control, synchronous control, JOG operation and
home return turns ON and the operation is initiated, this operation cannto be switched to
another operation even if another request turns on.
• Busy flags corresponding to each axis turn on during operation. Insert them as interlock
signals for each start request on user programs.
• The stop operations (system stop, limit stop, emergency stop and deceleration stop) are
preferentially activated even in other operations.

7.3.3 Operation When PLC Mode Changes From RUN To PROG.

The operation when the mode of the CPU unit changes from RUN to PROG. varies depending
on the setting of "RUN > PROG operation" of "MC common setting".
7-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp7Afp7mc32ecAfp7mc64ec

Table of Contents