15.8.5 Electronic Cam Setting Area
Unit
Axis no.
memory
no. (Hex)
UM 63F90
1
-UM 63F91
1
UM 63F92
1
UM 63F93
UM 63F94
1
-UM 63F95
UM 63F96
1
-UM 63FAF
(Note): The above table shows the unit memory numbers of axis number 1. For details of the whole configuration,
refer to "15.8.1 Configuration of Synchronous Control Setting Area".
15.8 Unit Memories (Synchronous Control Setting Area)
Name
Default Description
Cam control
synchronous
U1
master axis
cycle
Reserved for
-
system
Cam pattern
U1
number
Cam stroke
U1
amount
Reserved for
-
system
Set the cam control synchronous master cycle.
U1 to U2147483647
-
Set the registered cam pattern number to be used.
1 to 256
Displacement amount upper limit setting for cam
control
U1 to U2147483647
-
●: Available, -: Not available