 Conformity conditions to EMC Directive
Although this product conforms to EN61131-2 for the European EMC Directive (EMC Directive
2004/108/EC), the following wiring condition is required.
• Always use shielded twisted pair (STP) cables that are compatible with category 5e or higher.
• Attach ferrite cores at two points on the FP7 MC Unit side and Servo Amplifier A5B side, and
wire the cable to make a loop. Recommended ferrite core: Takeuchi Industry Co., Ltd. SFT-
72SN or equivalent
FP7
MC
50mm max.
3.2 Connection of Network
AMP
50mm max.
X2A