7.17

Pulse Related Instructions

Measuring the density of pulses

SPD
RnPCPU
RnCPU RnENCPU
(Process)
This instruction counts the device input only for the specified time.
Ladder
(s1)
FBD/LD
EN
ENO
s1
d
s2
■Execution condition
Instruction
SPD
Setting data
■Descriptions, ranges, and data types
Operand
Description
(s1)
Pulse input device number
(s2)
Measurement time, or the device number of the device
containing the measurement time (unit: ms)
(d)
Device for storing the measurement result
EN
Execution condition
ENO
Execution result
*1 Only labels assigned to device (X) can be used.
■Applicable devices
Operand
Bit
X, Y, M, L,
SM, F, B, SB,
FX, FY
*1
(s1)
(s2)
(d)
*1 Only X can be used. Note, however, that it can be used only within the range of the number of I/O points (the number of points that can
access I/O modules).
7 APPLICATION INSTRUCTIONS
894
7.17 Pulse Related Instructions
RnPCPU
RnSFCPU RnSFCPU
(Redundant)
(Standard)
(Safety)
(s2)
(d)
Execution condition
Word
J\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
ST
ENO:=SPD(EN,s1,s2,d);
Range
-32768 to 32767
Double word Indirect
U\G, J\,
Z
LT, LST,
U3E\(H)G
LC
Data type
Data type (label)
Bit
ANY_BOOL
16-bit signed binary
ANY16
16-bit signed binary
ANY16
Bit
BOOL
Bit
BOOL
Constant
specification
LZ
K, H E
*1
Others
$

Hide quick links: