Processing details
• These instructions search the (n) points of 32-bit binary data in the device specified by (s) for the minimum value, and store
the minimum value in the devices specified by (d) and (d)+1. Each instruction searches data starting from the device
specified by (s) and detects first the minimum value in the xth point from (s), and stores x in (d)+2 and the number of
minimum values in (d)+3.
(s)+1, (s)
22342001 (BIN)
37282010 (BIN)
(s)+3, (s)+2
(n)
(s)+5, (s)+4
22342001 (BIN)
(s)+7, (s)+6
59872019 (BIN)
(d), (d)+1: Minimum value
(d)+2: Location
(d)+3: Number of minimum values
Operation error
There is no operation error.
(d)
22342001 (BIN)
(d)+1
1
(d)+2
2
(d)+3
7 APPLICATION INSTRUCTIONS