Processing details
• These instructions calculate the common logarithm (using 10 as the base) of the value specified by (s), and store the
operation result in the device number specified by (d).
log10 (
(s)+1
(s)
Single-precision real number
• The value specified by (s) must be positive. (No negative value can be calculated.)
• If the operation result is -0 or an underflow occurs, the operation result turns out to 0.
• When an input value is set using the engineering tool, a rounding error may occur. Refer to the following for the precautions
on setting input values using the engineering tool.
Page 49 Precautions
Operation error
Error code
Description
(SD0)
The value input to (s) is -0, a subnormal number, NaN (not a number), or .
3402H
3405H
An out-of-range value is set to (s).
• The specified value is a negative number.
• The specified value is 0.
7 APPLICATION INSTRUCTIONS
836
7.9 Real Number Instructions
)
(d)+1
Single-precision real number
(d)