Deleting Data From Data Table - Mitsubishi Electric MELSEC iQ-R Series Programming Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Deleting data from data table

FDEL(P)
RnPCPU
RnPCPU
RnCPU RnENCPU
(Process)
(Redundant)
These instructions delete the data at the (n)th position in the data table.
Ladder
(s)
(d)
(n)
FBD/LD
EN
ENO
s
d
n
■Execution condition
Instruction
FDEL
FDELP
Setting data
■Descriptions, ranges, and data types
Operand
Description
(s)
Device where the data to be deleted is stored
(d)
Start device of table
(n)
Deletion position in the table
EN
Execution condition
ENO
Execution result
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
■Applicable devices
Operand
Bit
X, Y, M, L,
J\
SM, F, B, SB,
FX, FY
(s)
(d)
(n)
RnSFCPU RnSFCPU
(Standard)
(Safety)
Execution condition
Word
T, ST, C, D, W,
U\G, J\,
SD, SW, FD, R,
U3E\(H)G
ZR, RD
ST
ENO:=FDEL(EN,s,n,d);
ENO:=FDELP(EN,s,n,d);
Range
Data type
16-bit signed binary
Word
0 to 65535
16-bit unsigned binary
Bit
Bit
Double word Indirect
Z
LT, LST,
LZ
LC
7 APPLICATION INSTRUCTIONS
7.5 Data Table Operation Instructions
Data type (label)
ANY16
*1
ANY16
ANY16
BOOL
BOOL
Constant
Others
specification
K, H E
$
7
591

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents