• This instruction disables execution of interrupt programs with the interrupt pointer numbers specified by (s) or lower.
Interrupt priority setting
I No.
I50
I51
DI
A
B
I50
B
I51
A: Sequence program
B: Interrupt program
(1) Interrupt disabled section for priority 6 to 8 (Interrupt enabled section for priority 1 to 5)
(2) The interrupt program can be executed because its priority is 5.
(3) The interrupt program cannot be executed because its priority is 6.
K6
(1)
FEND
(2)
IRET
(3)
IRET