Ba000010 To Ba400002 Partition Firmware Srcs - IBM BladeCenter JS12 Problem Determination And Service Manual

Ibm power6 architecture
Table of Contents

Advertisement

BA000010 to BA400002 Partition firmware SRCs

The power-on self-test (POST) might display an error code that the partition
firmware detects. Try to correct the problem with the suggested action.
Table 14 describes error codes that might be displayed if POST detects a problem.
The description also includes suggested actions to correct the problem.
Note: For problems persisting after completing the suggested actions, see
"Checkout procedure" on page 186 and "Solving undetermined problems" on page
231.
Table 14. BA000010 to BA400002 Partition firmware SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Error code
BA000010
BA000020
BA000030
BA000031
BA000032
48
JS12 Type 7998: Problem Determination and Service Guide
Description
The device data structure is corrupted
Incompatible firmware levels were
found
An lpevent communication failure
occurred
An lpevent communication failure
occurred
The firmware failed to register the
lpevent queues
Action
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.