Baxxyyyy Partition Firmware Srcs - IBM Flex System p270 Compute Node Installation And Service Manual

Table of Contents

Advertisement

B700F108 • B700F130
B700F108
Explanation: A firmware error caused the system to terminate.
Response:
1. Collect the event log information.
2. Go to Isolating firmware problems.
B700F10A
Explanation: System firmware detected an error
Response: Look for and correct B1xxxxxx errors.
B700F10B
Explanation: A processor resource has been disabled due to hardware problems
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B700F10C
Explanation: The platform LIC detected an internal problem performing Partition Mobility.
Response:
1. Collect the event log information.
2. Go to Isolating firmware problems.
B700F120
Explanation: Informational system log entry only.
Response: No corrective action is required.
B700F130
Explanation: Thermal Power Management Device firmware error was detected.
Response: Check for server firmware updates; then, install the updates if available.

BAxxyyyy partition firmware SRCs:

The power-on self-test (POST) might display an error code that the partition firmware detects. Try to
correct the problem with the suggested action.
180
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents