IBM BladeCenter JS12 Problem Determination And Service Manual page 57

Ibm power6 architecture
Table of Contents

Advertisement

Table 13. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
4401
4402
4705
4710
4714
4788
5120
5121
5122
5123
5190
5191
5209
5219
5300
5301
Description
System firmware failure. The system
firmware detected an internal problem.
A system firmware error occurred while
attempting to allocate the memory
necessary to create a platform dump.
System firmware failure. A problem
occurred when initializing, reading, or
using the system VPD. The Capacity on
Demand function is not available.
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
System firmware detected an error
System firmware detected a
programming problem for which a
platform dump may have been initiated.
An error occurred during a search for
the load source.
Informational system log entry only.
Operating system error. The server
firmware detected a problem in an
operating system.
System firmware detected a virtual I/O
configuration error.
Informational system log entry only.
Informational system log entry only.
System firmware detected a failure
while partitioning resources. The
platform partitioning code encountered
an error.
User intervention required. The system
detected a problem with the partition
configuration.
Action
Go to "Isolating firmware problems" on page
222.
Go to "Isolating firmware problems" on page
222.
Restart the system.
No corrective action is required.
No corrective action is required.
No corrective action is required.
If the system is not exhibiting problematic
behavior, you can ignore this error. Otherwise,
go to "Isolating firmware problems" on page
222.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to "Isolating firmware problems" on
page 222.
If the partition fails to startup, go to "Isolating
firmware problems" on page 222. Otherwise,
no corrective action is required.
No corrective action is required.
Check for error codes in the partition that is
reporting the error and take the appropriate
actions for those error codes.
1. Use the Integrated Virtual Manager (IVM)
to verify or reconfigure the invalid virtual
I/O configuration.
2. Check for server firmware updates; then,
install the updates if available.
No corrective action is required.
No corrective action is required.
Check the management-module event log for
error codes; then, take the actions associated
with those error codes.
Use the Integrated Virtual Manager (IVM) to
reallocate the system resources.
Chapter 2. Diagnostics
43

Advertisement

Table of Contents
loading

Table of Contents