. 140 Solving undetermined problems . . 231 Service request numbers (SRNs) . . 141 Calling IBM for service . . 232 Using the SRN tables . . 142 101-711 through FFC-725 SRNs . 142 Chapter 3. Parts listing, Type 7998 A00-FF0 through A24-xxx SRNs .
Page 6
Removing a memory module . . 248 Hardware service and support . 283 Installing a memory module . . 249 IBM Taiwan product service . . 283 Removing the management card . . 250 Installing the management card . . 252 Appendix B.
Make sure that the insulation is not frayed or worn. 4. Remove the cover. 5. Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations. 6. Check inside the computer for any obvious unsafe conditions, such as metal filings, contamination, water or other liquid, or signs of fire or smoke damage.
Guidelines for servicing electrical equipment Observe the guidelines for servicing electrical equipment. v Check the area for electrical hazards such as moist floors, nongrounded power extension cords, and missing safety grounds. v Use only approved tools and test equipment. Some hand tools have handles that are covered with a soft material that does not provide insulation from live electrical current.
Safety statements Important: Each caution and danger statement in this documentation is labeled with a number. This number is used to cross reference an English-language caution or danger statement with translated versions of the caution or danger statement in the Safety Information document. For example, if a caution statement is labeled, ″Statement 1,″...
Page 11
Statement 2 CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
Page 12
Statement 4 ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) CAUTION: Use safe practices when lifting. Statement 5 CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device.
Page 13
CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components.
Page 14
JS22 Type 7998: Problem Determination and Service Guide...
Replaceable components are of three types: v Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. v Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for your blade server.
Features and specifications Features and specifications of the IBM BladeCenter JS22 Type 7998 blade server are summarized in this overview. JS22 Type 7998: Problem Determination and Service Guide...
Page 17
The JS22 blade server is used in an IBM BladeCenter H (8852), BladeCenter HT (8740 and 8750), or BladeCenter S (8886) unit. Notes: v Power, cooling, removable-media drives, external ports, and advanced system management are provided by the BladeCenter unit.
Supported DIMMs The BladeCenter JS22 Type 7998 blade server contains four angled memory connectors for industry-standard registered dual inline memory modules (RDIMMs). The total memory capacity ranges from a minimum of 2 GB to a maximum of 32 GB. See Chapter 3, “Parts listing, Type 7998,” on page 235 for memory modules that you can order from IBM.
Page 19
Keyboard/video select button: When you use an operating system that supports a local console and keyboard, press this button to associate the shared BladeCenter unit keyboard and video ports with the blade server. Notes: v The operating system in the blade server must provide USB support for the blade server to recognize and use the keyboard, even if the keyboard has a PS/2-style connector.
Page 20
Lit continuously: The blade server has power and is turned on. Note: The enhanced service processor (BMC) can take as long as three minutes to initialize after you install the BladeCenter JS22 blade server, at which point the LED begins to flash slowly.
Note: The enhanced service processor (BMC) can take as long as three minutes to initialize after you install the BladeCenter JS22 blade server, at which point the LED begins to flash slowly. v Start the blade server automatically when power is restored after a power failure.
Shut down the operating system before you turn off the blade server. See the operating-system documentation for information about shutting down the operating system. You can turn off the blade server in one of the following ways. v Turn off the blade server by pressing the power-control button for at least 5 seconds.
System-board connectors Blade server components attach to the connectors on the system board. Figure 2 shows the connectors on the system board in the blade server. DIMM 3 (P1-C1) DIMM 4 (P1-C2) Light Path DIMM 2 (P1-C3) Diagnostics button (blue) DIMM 1 (P1-C4) Control panel Management Card (P1-C5)
System-board LEDs Use the illustration of the LEDs on the system board to identify a light emitting diode (LED). Remove the blade server from the BladeCenter unit, open the cover to see any error LEDs that were turned on during error processing, and use Figure 3 to identify the failing component.
Error checking hardware ranges from parity error detection coupled with processor instruction retry and bus retry, to ECC correction on caches and system buses. IBM hardware error checkers have these distinct attributes: v Continuous monitoring of system operations to detect potential calculation errors...
The AIX-based stand-alone Diagnostics CD is in the ship package and is also available from the IBM Web site. Boot the CD from a CD drive or from an AIX network installation manager (NIM) server if the blade server cannot boot to an operating system, no matter which operating system is installed.
Note: If you power off the blade through the management module while the service processor is performing a dump, platform dump data is lost. You might be asked to retrieve a dump to send it to IBM Support for analysis. The location of the dump data varies per operating system platform.
v Collect an AIX dump from the /var/adm/platform directory. v Collect a Linux dump from the /var/log/dump directory. v Collect an Integrated Virtualization Manager (IVM) dump from the IVM-managed JS22 blade server through the Manage Dumps task in the IVM console.
To use reference codes effectively, use them in conjunction with other service and support procedures. The BladeCenter JS22 Type 7998 blade server produces several types of codes. Progress codes: The power-on self-test (POST) generates eight-digit status codes that are known as checkpoints or progress codes, which are recorded in the management-module event log.
System reference codes (SRCs) System reference codes indicate a server hardware or software problem that can originate in hardware, in firmware, or in the operating system. A blade server component generates an error code when it detects a problem. An SRC identifies the component that generated the error code and describes the error.
Dxxxxxxx - Dump checkpoint (must hang to indicate an error) To find a description of a SRC that is not listed in this JS22 blade server documentation, refer to the POWER6 Reference Code Lookup page at https://www-01.ibm.com/servers/resourcelink/lib03030.nsf/pages/eClipzML/ $file/refCode.html. 1xxxyyyy SRCs The 1xxxyyyy system reference codes are system power control network (SPCN) reference codes.
Page 32
Table 4. 1xxxyyyy SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 33
Table 4. 1xxxyyyy SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 34
Table 4. 1xxxyyyy SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 35
Table 4. 1xxxyyyy SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Table 4. 1xxxyyyy SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 37
Table 5. 6xxxyyyy SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Table 5. 6xxxyyyy SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
A700yyyy Licensed internal code SRCs An A7xx SRC is a licensed internal code SRC that is deprecated in favor of a corresponding B7xx SRC. B7xx SRCs are described in “B700xxxx Licensed internal code SRCs” on page 39. Table 8. A700yyyy Licensed internal code SRCs Attention code Description Action...
Page 40
Table 9. AA00E1A8 to AA260005 Partition firmware attention codes (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 41
Table 9. AA00E1A8 to AA260005 Partition firmware attention codes (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
To find a description of a SRC that is not listed in this JS22 blade server documentation, refer to the POWER6 Reference Code Lookup page at https://www-01.ibm.com/servers/resourcelink/lib03030.nsf/pages/eClipzML/ $file/refCode.html. Table 10 describes error codes that might occur if POST detects a problem. The description also includes suggested actions to correct the problem.
B200xxxx Logical partition SRCs A B200xxxx system reference code (SRC) is an error code that is related to logical partitioning. Table 11 describes error codes that might be displayed if POST detects a problem. The description also includes suggested actions to correct the problem. Note: For problems persisting after completing the suggested actions, see “Checkout procedure”...
Page 44
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 45
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 46
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 47
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 48
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 49
600A A problem occurred during the Contact IBM support, as described in Appendix A, startup of a partition. The partition “Getting help and technical assistance,” on page 281. could not reserve the memory required for IPL.
Page 50
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 51
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 52
Verify that processor resources are assigned to the partition. 8160 A problem occurred during the Contact IBM support, as described in Appendix A, migration of a partition. “Getting help and technical assistance,” on page 281. 8161 A problem occurred during the Contact IBM support, as described in Appendix A, migration of a partition.
Table 11. B200xxxx Logical partition SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 54
No immediate action is necessary. storage condition Continue running the system normally. At the earliest convenient time or service window, work with IBM Support to collect a platform dump and restart the system; then, go to “Isolating firmware problems” on page 222. 0201 System firmware detected an error.
Page 55
Table 12. B700xxxx Licensed internal code SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 56
B1xxxxxx errors, or if correcting the errors does not correct the problem, contact IBM support to reset the server firmware settings. Attention: Resetting the server firmware settings results in the loss of all of the partition data that is stored on the service processor.
Page 57
Table 12. B700xxxx Licensed internal code SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 58
B700 xxxx Error Codes Description Action 5302 An unsupported Preferred Operating Work with IBM support to select a supported System was detected. Preferred Operating System; then, re-IPL the system. The Preferred Operating System specified is not supported. The IPL will not continue.
Page 59
Table 12. B700xxxx Licensed internal code SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 60
Table 12. B700xxxx Licensed internal code SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 61
Table 12. B700xxxx Licensed internal code SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
BA000010 to BA400002 Partition firmware SRCs The power-on self-test (POST) might display an error code that the partition firmware detects. Try to correct the problem with the suggested action. Table 13 describes error codes that might be displayed if POST detects a problem. The description also includes suggested actions to correct the problem.
Page 63
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 64
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 65
“Replacing the Tier 2 system-board and chassis assembly” on page 270. BA00E830 Failure when initializing ibm,event-scan 1. Go to “Checkout procedure” on page 186. 2. Replace the system-board and chassis assembly, as described in “Replacing the Tier 2 system-board and chassis assembly”...
Page 66
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 67
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 68
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 69
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 70
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 71
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 72
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 73
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 74
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 75
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 76
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 77
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 78
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 79
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 80
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 81
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 82
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 83
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 84
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 85
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 86
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 87
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 88
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 89
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 90
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 91
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 92
Error code Description Action BA180100 The FDDI adapter Fcode driver is not IBM may produce a compatible driver in the supported on this server. future, but does not guarantee one. BA180101 Stack underflow from fibre-channel 1. Go to “Checkout procedure” on page 186.
Page 93
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 94
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 95
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 96
Failed to reboot the system after a Restart the blade server. firmware flash update BA278009 The operating system’s server firmware Go to the IBM download site at update management tools are www14.software.ibm.com/webapp/set2/sas/ incompatible with this system. f/lopdiags/home.html to download the latest version of the service aids package for Linux.
Page 97
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 98
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 99
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 100
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Page 101
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
Table 13. BA000010 to BA400002 Partition firmware SRCs (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions. v See Chapter 3, “Parts listing, Type 7998,”...
The management module can display the most recent 32 SRCs and time stamps. Manually refresh the list to update it. Select Blade Service Data → blade_name in the management module to see a list of the 32 most recent SRCs. Table 14.
Page 104
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 105
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 106
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 107
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 108
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 109
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 110
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 111
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 112
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Table 15. C1001F00 to C1645300 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 114
The virtual service processor can start a variety of operating systems. Some codes are specific to an operating system and therefore, do not apply to all operating systems. Table 16 lists the progress codes that might be displayed during the power-on self-test (POST), along with suggested actions to take if the system hangs on the progress code.
Page 115
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 116
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 117
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 118
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 119
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 120
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 121
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 122
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Table 16. C2001000 to C20082FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Table 17 shows the form of the C700xxxx progress codes, where xxxx can be any number or letter. v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 125
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 126
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 127
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 128
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 129
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 130
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 131
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 132
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 133
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 134
“Replacing the Tier 2 system-board and chassis assembly” on page 270. CA00E198 The system is rebooting to enact changes Go to “Boot problem resolution” on page 193. that were specified in ibm,client-architecture-support JS22 Type 7998: Problem Determination and Service Guide...
Page 135
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 136
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 137
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 138
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 139
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 140
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 141
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 142
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 143
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 144
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Table 18. CA000000 to CA2799FF checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 146
Table 19. D1001xxx to D1xx3FFF dump codes v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 147
Table 19. D1001xxx to D1xx3FFF dump codes (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 148
Table 19. D1001xxx to D1xx3FFF dump codes (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 149
Table 19. D1001xxx to D1xx3FFF dump codes (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 150
Table 19. D1001xxx to D1xx3FFF dump codes (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Page 151
Table 19. D1001xxx to D1xx3FFF dump codes (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
D1xx3y01 to D1xx3yF2 Service processor dump codes: These D1xx3yxx service processor dump codes use the format: D1xx3yzz, where xx indicates the cage or node ID that the dump component is processing, y increments from 0 to F to indicate that the system is not hung, and zz indicates the command being processed.
Page 153
Table 20. D1xx3y01 to D1xx3yF2 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Table 20. D1xx3y01 to D1xx3yF2 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Table 21. D1xx900C to D1xxC003 checkpoints (continued) v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, you can stop performing the remaining actions.
Note: The “diagela” service aid is part of the Linux service aids for hardware diagnostics. The service aids are separate from the operating system and are available for download from the Service and productivity tools for Linux on POWER systems site. Using the SRN tables The service request number (SRN) list is in numerical sequence.
Page 157
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 103-151 The time-of-day battery failed. 1. Go to “Removing the battery” on page 263 to start the battery replacement procedure. 2. Go to “Installing the battery” on page 264 to complete the procedure. 109-200 The system crashed while you running it.
Page 158
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 651-140 Display Character test failed. Note: Diagnostic will provide this SRN but there is no action to be taken. Do not perform operator panel test from diagnostics. 651-151 152 2E2 Sensor indicates a voltage is outside the normal range.
Page 159
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 651-613 External cache ECC single-bit error. Go to “Performing the checkout procedure” on page 187. 651-614 System bus time-out error. Go to “Performing the checkout procedure” on page 187. 651-615 Time-out error waiting for I/O.
Page 160
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 651-66A Correctable error threshold exceeded. Go to “Performing the checkout procedure” on page 187. 651-66B Correctable error threshold exceeded. Go to “Performing the checkout procedure” on page 187. 651-674 Failed memory module. Go to “Performing the checkout procedure” on page 187. 651-675 Failed memory module.
Page 161
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 651-734 Intermediate or system bus data parity error. Go to “Performing the checkout procedure” on page 187. 651-735 Intermediate or system bus time-out error. Go to “Performing the checkout procedure” on page 187. 651-736 Intermediate or system bus time-out error.
Page 162
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 651-786 304 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page 187. 651-789 2CD 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page 187. 651-78A 2CE 214 Uncorrectable memory error.
Page 163
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 651-841 152 2E2 Sensor detected a voltage outside of the normal range. Go to “Performing the checkout procedure” on page 187. 651-842 Sensor detected an abnormally high internal temperature. Make sure that: 1.
Page 164
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 652-731 A non-critical error has been detected: intermediate or system bus address parity error. Schedule deferred maintenance. Go to “Performing the checkout procedure” on page 187. 652-732 A non-critical error has been detected: intermediate or system bus data parity error. Schedule deferred maintenance.
Page 165
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 815-100 The floating-point processor test failed. Go to “Performing the checkout procedure” on page 187. 815-101 Floating point processor failed. Go to “Performing the checkout procedure” on page 187. 815-102 Floating point processor failed.
Page 166
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 887-113 External loopback (twisted pair) parity test failed. Go to “Performing the checkout procedure” on page 187. 887-114 Ethernet loopback (twisted pair) fairness test failed. Go to “Performing the checkout procedure”...
Page 167
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 252B-101 252B Adapter configuration error. 1. Check the BladeCenter management-module event log. If an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. Replace any parts reported by the diagnostic program. 3.
Page 168
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 252B-718 252B 293 Temporary PCI bus error detected by adapter. 1. Check the BladeCenter management-module event log. If an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2.
Page 169
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 254E-702 254E 221 Error log analysis indicates permanent adapter failure is reported on the other port of this adapter. Go to “Performing the checkout procedure” on page 187. 2567-xxx 2567 USB integrated system-board and chassis assembly.
Page 170
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 256D-702 256D 221 Error Log Analysis indicates permanent adapter failure is reported on the other port of this adapter. 1. Check the BladeCenter management-module event log. If an error was recorded by the system, see “POST progress codes (checkpoints)”...
Page 171
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 2604-705 2604 Error Log Analysis indicates that a parity error has been detected for the Fibre Channel adapter card. The adapter must be replaced immediately. Failure to do so could result in data being read or written incorrectly.
Page 172
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 2607-706 2607 Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre Channel adapter card. This adapter was successfully taken off-line. It will remain off-line until reconfigured or the system is rebooted.
Table 22. 101-711 through FFC-725 SRNs (continued) Description and Action 2640-114 2640 IDE disk diagnostic failure. Go to “Performing the checkout procedure” on page 187. 2640-115 2640 2631 IDE disk error on open or configuring device system-board and chassis assembly - IDE controller.
Page 174
Note: Some SRNs in this sequence might have 4 rather than 3 digits after the dash (–). Table 23 shows the meaning of an x in any of the following SRNs, such as A01-00x. Table 23. Meaning of the last character (x) after the hyphen Number Meaning Replace all FRUs listed...
Page 175
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A01-06x Time-out error waiting for I/O. 1. Check the BladeCenter management-module event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. If no entry is found, replace the system-board and chassis assembly.
Page 176
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A02-06x Memory Data error (Bad data going to 1. Check the BladeCenter management-module memory). event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2.
Page 177
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A03-05x I/O Error on non-PCI bus. 1. Check the BladeCenter management-module event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. If no entry is found, replace the system-board and chassis assembly.
Page 178
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A03-16x I/O Expansion unit not in an operating 1. Check the BladeCenter management-module state. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2.
Page 179
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A05-06x System shutdown due to abnormally 1. Make sure that: high internal temperature. a. The room ambient temperature is within the system operating environment. b. There is unrestricted air flow around the system.
Page 180
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A05-21x System shutdown due to Over 1. Make sure that: temperature condition. a. The room ambient temperature is within the system operating environment. b. There is unrestricted air flow around the system.
Page 181
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A0D-09x Service Processor error accessing Vital 1. Check the BladeCenter management-module Product Data EEPROM. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2.
Page 182
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A0D-36x Other IPL Diagnostic Error. 1. Check the BladeCenter management-module event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. If no entry is found, replace the system-board and chassis assembly.
Page 183
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A11-01x A non-critical error has been detected, a 1. Check the BladeCenter management-module CPU internal error. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2.
Page 184
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A11-550 Recoverable errors on resource indicate 1. If repair is not immediately available, reboot a trend toward an unrecoverable error. and the resource will be deconfigured; However, the resource could not be operations can continue in a degraded mode.
Page 185
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A12-07x A non-critical error has been detected, a 1. Check the BladeCenter management-module memory bus/switch internal error. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)”...
Page 186
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A12-16x A non-critical error has been detected, a 1. Check the BladeCenter management-module system bus internal hardware/switch event log; if an error was recorded by the error. system, see “POST progress codes (checkpoints)”...
Page 187
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A13-06x A non-critical error has been detected, a 1. Check the BladeCenter management-module mezzanine bus address parity error. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)”...
Page 188
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A13-16x A non-critical error has been detected, 1. Check the BladeCenter management-module an I/O expansion unit not in an event log; if an error was recorded by the operating state. system, see “POST progress codes (checkpoints)”...
Page 189
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A15-12x Sensor detected redundant power 1. Check the BladeCenter management-module supply failure. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. If no entry is found, replace the system-board and chassis assembly.
Page 190
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A15-22x Fan failure and Over temperature 1. Check the BladeCenter management-module condition. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. If no entry is found, replace the system-board and chassis assembly.
Page 191
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A1D-05x A non-critical error has been detected, a 1. Check the BladeCenter management-module service processor error accessing special event log; if an error was recorded by the registers. system, see “POST progress codes (checkpoints)”...
Page 192
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A1D-19x A non-critical error has been detected, a 1. Check the BladeCenter management-module service processor error accessing real event log; if an error was recorded by the time clock/time-of-day clock. system, see “POST progress codes (checkpoints)”...
Page 193
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A1D-34x A non-critical error has been detected: 1. Check the BladeCenter management-module Wire Test Error. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2.
Table 24. A00-FF0 through A24-xxx SRNs (continued) Description FRU/action A24-xxx Spurious interrupts have exceeded 1. Check the BladeCenter management-module threshold. event log; if an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. Replace part numbers reported by the diagnostic program.
Page 195
Table 25. ssss-102 through ssss-640 SRNs (continued) Description and action ssss-108 ssss The bus test failed. 1. Check the BladeCenter management-module event log. If an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2. Replace any parts reported by the diagnostic program. 3.
Page 196
Table 25. ssss-102 through ssss-640 SRNs (continued) Description and action ssss-122 ssss A SCSI reservation conflict error. 1. Check the BladeCenter management-module event log. If an error was recorded by the system, see “POST progress codes (checkpoints)” on page 88. 2.
Page 197
The ventilation holes in the blade server bezel are not blocked. v The management-module event log is not reporting any system environmental warnings. 2. If the problem remains, call IBM support. ssss-140 199 252B Error log analysis indicates poor signal quality.
Failing function codes 151 through 2D02 Failing function codes (FFCs) identify a function within the system unit that is failing. Table 26 describes the component that each function code identifies. Note: When replacing a component, perform system verification for the component.
Page 199
Table 26. Failing function codes 151 through 2D02 (continued) Description and notes System-board and chassis assembly (System/SP interface logic problem) System-board and chassis assembly (I2C primary) System-board and chassis assembly (I2C secondary) System-board and chassis assembly (VPD module) System-board and chassis assembly (Power controller) System-board and chassis assembly (Fan sensor problem) System-board and chassis assembly (Thermal sensor problem) System-board and chassis assembly (Voltage sensor problem)
Error logs ™ The power-on self-test (POST), the POWER Hypervisor (PHYP), and the service processor write errors to the BladeCenter management module event log. Select the Monitors → Event Log option in the management module Web interface to view entries that are currently stored in the management-module event log. This log includes entries for events that are detected by the blade servers.
v If the blade server hangs on a POST checkpoint, see “POST progress codes (checkpoints)” on page 88. If the blade server is halted and no error message is displayed, see “Troubleshooting tables” on page 194 and “Solving undetermined problems” on page 231. v For intermittent problems, check the management-module event log and “POST progress codes (checkpoints)”...
Page 202
Step 005 Perform the following steps: Note: When possible, run AIX online diagnostics in concurrent mode. AIX online diagnostics perform more functions than the stand-alone Diagnostics. 1. Perform the AIX online diagnostics, see “Starting AIX concurrent diagnostics” on page 189. Record any diagnostic results and see the “Service request numbers (SRNs)”...
“Service request numbers (SRNs)” on page 141. This ends the Linux procedure. For more information about installing and using all supported operating systems, search the IBM Support Site. Verifying the partition configuration Perform this procedure if there is a configuration problem with the system or a logical partition.
Starting stand-alone diagnostics from a CD Perform these procedures to start the stand-alone diagnostics from a CD. These procedures can be used if the blade server is running a Linux operating system or if an AIX operating system cannot start the concurrent diagnostics program. You can download the latest version of the stand-alone diagnostics from the Standalone Diagnostics CD page.
Starting stand-alone diagnostics from a NIM server Perform this procedure to start the stand-alone diagnostics from a network installation management (NIM) server. Note: See Network Installation Management in the AIX Information Center for information about configuring the blade server as a NIM server client. Also see the Configuring the NIM Master and Creating Basic Installation Resources Web page.
7. When testing is complete, press F3 until the Diagnostic Operating Instructions screen is displayed; then press F3 again to exit the diagnostic program. Using the diagnostics program Follow the basic procedures for running the diagnostics program. 1. Start the diagnostics from the AIX operating system, from a CD, or from a management server.
3. When testing is complete, press F3 until the Diagnostic Operating Instructions screen is displayed; then press F3 again to exit the diagnostic program. Boot problem resolution Depending on the boot device, a checkpoint might be displayed in the list of checkpoints in the management module for an extended period of time while the boot image is retrieved from the device.
3. If you are attempting to boot from the CD or DVD drive: a. From the BladeCenter management-module Web interface, make sure that the media tray is assigned to your blade server: Blade Tasks → Remote Control. b. Turn the blade server power off; then, turn it on and retry the boot operation.
If these symptoms relate to shared BladeCenter unit resources, see “Solving shared BladeCenter resource problems” on page 225. If you cannot find the problem in these tables, see “Running the diagnostics program” on page 189 for information about testing the blade server. If you have just added new software or a new optional device and the blade server is not working, complete the following steps before using the troubleshooting tables:...
Intermittent problems Identify intermittent problem symptoms and corrective actions. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Management module service processor problems Determine if a problem is a management module service processor problem and, if so, the corrective action to take. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
Monitor or video problems View monitor or video problem symptoms to find corrective actions. Some IBM monitors have their own self-tests. If you suspect a problem with your monitor, see the documentation that comes with the monitor for instructions for testing and adjusting the monitor.
Page 213
Make sure that the monitor cable is connected to the video port on the you direct it to a working blade BladeCenter management module. Some IBM monitors have their own self-tests. If server, or goes blank when you you suspect a problem with the monitor, see the information that comes with the start some application programs monitor for adjusting and testing instructions.
Network connection problems Identify network connection problem symptoms and what corrective actions to take. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician. Symptom Action An IBM optional device that 1. Make sure that: was just installed does not v The option is designed for the blade server. See the ServerProven list at work.
Power problems Identify power problem symptoms and what corrective actions to take. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
3. Check the bus and I/O adapter allocations for the partition. Verify that the partition has load source and console I/O resources. 4. Check the IPL mode of the system or failing partition. 5. For further assistance, contact IBM Support. Chapter 2. Diagnostics...
Page 218
3. Install new memory DIMMs, as described in “Installing a memory module” on page 249. See “Supported DIMMs” on page 4 for more information. NEXTLVL Contact IBM Support. Symbolic CRU PIOCARD The hardware that 1. Collect the error log information.
Service processor problems The baseboard management controller (BMC) is a flexible service processor that provides error diagnostics with associated error codes, and fault isolation procedures for troubleshooting. Note: Resetting the service processor causes a POWER6 reset/reload, which generates a dump. The dump is recorded in the management module event log. The reset/reload dump occurs whenever the service processor resets, such as when resetting the service processor through the management module Web interface or through the management module command line interface.
Page 220
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Page 221
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Page 222
2. If the problem persists, replace the system board and chassis assembly, as described in “Replacing the Tier 2 system-board and chassis assembly” on page 270. FSPSP06 The service processor Contact IBM Support. reported a suspected intermittent problem. FSPSP07 The time of day has 1.
Page 223
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Page 224
Collect the dump for support and power off and power on the blade server. 5. If an A1xx SRC has not remained more than 40 minutes, call IBM Support. FSPSP16 Save any error log Contact IBM Support.
Page 225
ID. Record the resource ID and be found in the Vital the model of the system. Product Data (VPD) 2. Call IBM Support to find out what CRU the resource ID represents. table. 3. Replace the CRU that the resource ID represents. The system has...
Page 226
1. Set the enclosure feature code using SMS, which automatically resets the service processor. 2. If the problem persists, call IBM Support. If you do not see your reason code listed, call IBM Support. JS22 Type 7998: Problem Determination and Service Guide...
Page 227
Action Procedure Code FSPSP34 The memory cards Install a DIMM for each of the dual processors on the BladeCenter JS22 are plugged in an Type 7998 blade server. Install the first pair in DIMM connectors 2 and 4. invalid configuration Look for the following error codes in order.
Page 228
PSI link. FSPSP48 A diagnostics If the CRUs called out before this procedure do not fix the problem, function detects an contact IBM Support. external processor interface problem. FSPSP49 A diagnostic function If the CRUs called out before this procedure do not fix the problem, detects an internal contact IBM Support.
Page 229
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Page 230
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Software problems Use this information to recognize software problem symptoms and to take corrective actions. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Light path diagnostics Light path diagnostics is a system of LEDs on the control panel and on the system board of the blade server. When an error occurs, LEDs are lit throughout the blade server. If the control panel indicates an error, use the descriptions of the LEDs to diagnose the problem and take corrective action.
Hard disk drive error LED (P1-D1 SAS 0) System board error LED (P1 SYS BRD) DIMM 3 error LED (P1-C1 DIMM3) DIMM 4 error LED (P1-C2 DIMM4) Light path diagnostics switch PCI-X expansion option error LED (P1-C6 PCI-X) DIMM 2 error LED (P1-C3 DIMM2) DIMM 1 error LED (P1-C4 DIMM1) PCI-E high-speed expansion card error LED (P1-C7 PCI-E) Management card error LED...
Page 234
Table 31. Light path diagnostic LED descriptions (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which components are FRUs.
Page 235
1. Make sure that the I/O expansion option is card error supported, as described on the ServerProven Web site. See P1-C6 PIOCARD http://www.ibm.com/servers/eserver/ serverproven/compat/us/. 2. Reseat the I/O expansion option, as described in “Removing and installing an I/O expansion card” on page 256.
Isolating firmware problems You can use this procedure to isolate firmware problems. To isolate a firmware problem, follow the procedure until the problem is solved. 1. If the blade server is operating, shut down the operating system and turn off the blade server.
To force the blade server to start the PERM (permanent) image, complete the following procedure. 1. Access the Advanced Management Module menus. 2. Click Blade Tasks → Configuration → Boot Mode. 3. Click the appropriate JS22 blade server in the list of blade servers in the BladeCenter unit.
1. Start the diagnostics program. See “Running the diagnostics program” on page 189. The online BladeCenter information center is available in the at IBM Systems Information Center. 2. From the Function Selection menu, select Task Selection and press Enter.
4. From the Update and Manage System Flash menu, select Commit the Temporary Image and press Enter. 5. When the commit function is complete, press F3 until the Diagnostic Operating Instructions screen is displayed; then press F3 again to exit the diagnostic program.
12. Check for video problems, as described in “Solving shared video problems” on page 230. Solving shared keyboard problems Problems with BladeCenter shared resources might appear to be in the blade server, but might actually be a problem in a BladeCenter unit keyboard component.
Page 241
To check the general function of shared BladeCenter media tray resources, perform the following procedure. 1. Verify that the media-tray select button LED on the front of the blade server is lit. A lit media-tray select button LED shows that the blade server is connected to the shared media tray.
7. Troubleshoot one or more of the removable media drives if they are the only failing components. a. Reseat the following components: v Removable-media drive cable (if applicable) v Removable-media drive v Media tray cable (if applicable) v Media tray 8.
4. Verify that the installation of the I/O-module type is supported by the BladeCenter unit and blade server hardware. 5. Verify that the I/O modules for the network interface are installed in the correct BladeCenter bays. 6. Verify that the I/O modules for the network interface are configured correctly. 7.
Problems with BladeCenter shared resources might appear to be in the blade server, but might actually be a problem in a BladeCenter unit video component. Some IBM monitors have their own self-tests. If you suspect a problem with the monitor, see the information that comes with the monitor for instructions for adjusting and testing the monitor.
7. Replace the monitor cable, if applicable. 8. Replace the monitor. 9. Replace the management module. See the online information center or the Problem Determination and Service Guide or the Hardware Maintenance Manual and Troubleshooting Guide for your BladeCenter unit. If these steps do not resolve the problem, it is likely a problem with the blade server.
Calling IBM for service Call IBM for service after you collect as much as possible of the following information. Before calling for service, collect as much as possible of the following available...
Page 247
See Appendix A, “Getting help and technical assistance,” on page 281 for information about how to call IBM for service. Chapter 2. Diagnostics...
Page 248
JS22 Type 7998: Problem Determination and Service Guide...
Page 250
Replaceable components are of three types: v Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. v Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for your blade server.
Replaceable components are of three types: v Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. v Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for your blade server.
points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component. v When you are finished working on the blade server, reinstall all safety shields, guards, labels, and ground wires.
Returning a device or component If you are instructed to return a device or component, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Removing the blade server from a BladeCenter unit Remove the blade server from the BladeCenter unit to access options, connectors, and system-board indicators.
Always replace the blade server cover before installing the blade server. Perform the following procedure to install a blade server in a BladeCenter unit. 1. Go to http://www.ibm.com/systems/support/ to download the latest firmware for the blade server. Download the firmware so that you can use it later to update the blade server after you start it.
Page 255
2. Read “Safety” on page v and the “Installation guidelines” on page 237. 3. If you have not done so already, install any optional devices that you want, such as a SAS drive or memory modules. 4. Select the bay for the blade server. v See the online information or the Installation and User’s Guide that comes with your BladeCenter unit to verify that the bay you choose is powered.
Removing and replacing Tier 1 CRUs Replacement of Tier 1 customer-replaceable units (CRUs) is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation. The illustrations in this documentation might differ slightly from your hardware.
3. Carefully lay the blade server on a flat, static-protective surface, with the cover side up. 4. Press the blade-cover release on each side of the blade server and lift the cover open. 5. Lay the cover flat, or lift it from the blade server and store it for future use. Statement 21 CAUTION: Hazardous energy is present when the blade server is connected to the power...
1. Read “Safety” on page v and the “Installation guidelines” on page 237. 2. Lower the cover so that the slots at the rear slide down onto the pins at the rear of the blade server. Before you close the cover, verify that all components are installed and seated correctly and that you have not left loose tools or parts inside the blade server.
Installing the bezel assembly Install the bezel assembly. Bezel-assembly release Control-panel connector Control-panel cable Bezel-assembly release Bezel assembly Figure 11. Installing the bezel assembly 1. Connect the control-panel cable to the control-panel connector on the system board. 2. Carefully slide the bezel assembly onto the blade server until it clicks into place.
Removing the SAS hard disk drive Remove the SAS hard disk drive to install a new drive or to install certain expansion cards. SAS hard disk drive Figure 12. Removing a SAS hard disk Perform the following procedure to remove the SAS hard disk drive. 1.
Installing the SAS hard disk drive Install the SAS hard disk drive. Note: Do not install a SAS hard disk drive if you intend to install a standard-form-factor expansion card. The standard-form-factor expansion card occupies the same area as the hard disk drive. Figure 13 shows how to install the SAS drive.
7. Place the drive into the hard disk drive tray and push it toward the rear of the blade, into the connector until the drive moves past the lever at the front of the tray. Attention: Do not press on the top of the drive. Pressing the top might damage the drive.
5. Locate the DIMM connector that contains the DIMM that is to be replaced. See “System-board connectors” on page 9 for DIMM slot locations. Attention: To avoid breaking the DIMM retaining clips or damaging the DIMM connectors, open and close the clips gently. 6.
4. Carefully lay the blade server on a flat, static-protective surface, with the cover side up. 5. Open and remove the blade server cover. See “Removing the blade server cover” on page 242. 6. Locate the DIMM connectors on the system board. See the illustration in “System-board connectors”...
Page 265
Management card Retaining clip Figure 16. Removing the management card Perform the following procedure to remove the management card. 1. Read “Safety” on page v and the “Installation guidelines” on page 237. 2. Shut down the operating system, turn off the blade server, and remove the blade server from the BladeCenter unit.
Installing the management card Use this procedure to install the management card into the currently installed system board. If you are also installing a new system board, you must complete this procedure before installing the new system board. To install the management card, complete the following steps. Management card Retaining clip...
7. Install and close the blade server cover. See “Installing and closing the blade server cover” on page 243. Statement 21 CAUTION: Hazardous energy is present when the blade server is connected to the power source. Always replace the blade server cover before installing the blade server.
Page 268
3. Send a note requesting the VET activation code for your replacement management (anchor) card to the System p Capacity on Demand mailbox at pcod@us.ibm.com. Include the following fields and their values from the information you received after running the lsvet command:...
Page 269
Figure 18. System p Capacity on Demand Activation code Web page Otherwise, look for a VET entry with a date that aligns with your request date; then make a record of the corresponding VET activation code. 5. In an IVM session, use the chvet -o e -k activation_code command to enter the 34-character VET activation code for activating PowerVM virtualization.
6. In an IVM session, validate that the code entry is successful using the lsvet -t hist command. The command returns information that is similar to the following example: time_stamp=03/06/2008 16:25:08,"entry=[VIOSI05000400-0331] CoD advanced functions activation code entered, resource ID: CA1F, capabilities: 2820." time_stamp=03/06/2008 16:25:08,entry=[VIOSI05000403-0332] Virtual I/O server capability enabled.
Removing a small-form-factor expansion card Remove a small-form-factor expansion card. Expansion card Figure 19. Removing a small form factor (SFF) expansion card 1. Read “Safety” on page v and the “Installation guidelines” on page 237. 2. Shut down the operating system, turn off the blade server, and remove the blade server from the BladeCenter unit.
Installing a small-form-factor expansion card Install a small-form-factor expansion card to expand the I/O capabilities of the blade server. Expansion card Figure 20. Installing a small-form-factor expansion card To install a small-form-factor expansion card, complete the following steps: 1. Read “Safety” on page v and the “Installation guidelines” on page 237. 2.
7. Install and close the blade server cover. See “Installing and closing the blade server cover” on page 243. Statement 21 CAUTION: Hazardous energy is present when the blade server is connected to the power source. Always replace the blade server cover before installing the blade server.
Installing a standard-form-factor expansion card Install a standard-form-factor expansion card to expand the I/O capabilities of your blade server. Expansion bracket Expansion card Hard disk drive tray Figure 21. Installing a standard-form-factor expansion card To install a standard-form-factor expansion card, complete the following steps: 1.
9. Install and close the blade server cover. See “Installing and closing the blade server cover” on page 243. Statement 21 CAUTION: Hazardous energy is present when the blade server is connected to the power source. Always replace the blade server cover before installing the blade server.
3. Open and remove the blade server cover. See “Removing the blade server cover” on page 242. 4. Remove the horizontal (CFFh) CFFe expansion card, which is the larger card. a. Pull up on the camming lever to disengage the card from the connector. b.
1. Read “Safety” on page v and the “Installation guidelines” on page 237. 2. Shut down the operating system, turn off the blade server, and remove the blade server from the BladeCenter unit. See “Removing the blade server from a BladeCenter unit” on page 239. 3.
To order replacement batteries, call 1-800-426-7378 within the United States, and 1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada, call your IBM marketing representative or authorized reseller. v After you replace the battery: 1. Set the time and date.
Page 279
CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of.
Removing the hard disk drive tray You can remove the hard disk drive tray. Hard disk drive tray Figure 26. Removing the hard disk drive tray Perform the following procedure to remove the hard disk drive tray. 1. Read “Safety” on page v and the “Installation guidelines” on page 237. 2.
Installing the hard disk drive tray You can install the hard disk drive tray. Hard disk drive tray Figure 27. Installing the hard disk drive tray To install the hard disk drive tray, complete the following steps: 1. Place the drive tray into position on the system board and install the four screws to secure it.
4. Install the blade server into the BladeCenter unit. See “Installing the blade server in a BladeCenter unit” on page 240. Removing the expansion bracket You can remove the expansion bracket. Expansion bracket Figure 28. Removing the expansion bracket Perform the following procedure to remove the expansion bracket. 1.
Installing the expansion bracket You can install the expansion bracket. Expansion bracket Figure 29. Installing the expansion bracket To install the expansion bracket, complete the following steps: 1. Place the expansion bracket in position on the system board. 2. Secure the bracket to the system board with two screws from the option kit or from the removed drive tray.
Replacing the Tier 2 system-board and chassis assembly You can install this Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that is designated for the blade server. Replace the system board and chassis assembly. When replacing the system board, you will replace the system board, blade base (chassis), microprocessors, and heat sinks as one assembly.
Page 285
9. Install the bezel assembly. See “Installing the bezel assembly” on page 245 for instructions. 10. Install and close the blade server cover. See “Installing and closing the blade server cover” on page 243. Statement 21 CAUTION: Hazardous energy is present when the blade server is connected to the power source.
Page 286
JS22 Type 7998: Problem Determination and Service Guide...
(SMS) to configure the JS22 blade server. Updating the firmware IBM periodically makes firmware updates available for you to install on the blade server, the management module, or expansion cards in the blade server. Important: To avoid problems and to maintain proper system performance, always verify that the blade server BIOS, service processor, and diagnostic firmware levels are consistent for all blade servers within the BladeCenter unit.
3. Log on to the AIX or Linux system as root, or log on to the Virtual I/O Server/IVM alpha partition as padmin. 4. Type ls /tmp/fwupdate to identify the name of the firmware. The result of the command lists any firmware updates that you downloaded to the directory, such as the following update, for example: 01EA3xx_yyy_zzz 5.
v System management services (SMS) Use the system management services (SMS) utility to view information about your system or partition and to perform tasks such as setting up remote IPL, changing SCSI settings, and selecting boot options. The SMS utility can be used for AIX or Linux partitions.
SMS utility menu choices Select SMS tasks from the SMS utility main menu. Choices on the SMS utility main menu depend on the version of the firmware in the blade server. Some menu choices might differ slightly from these descriptions. v Select Language Select this choice to change the language that is used to display the SMS menus.
Ethernet controllers, see the Broadcom NetXtreme Gigabit Ethernet Software CD that comes with the blade server. For updated information about configuring the controllers, see http://www.ibm.com/systems/support/. The Ethernet controllers in your blade server support failover, which provides automatic redundancy for the Ethernet controllers. Failover capabilities vary per BladeCenter unit.
Blade server Ethernet controller enumeration The enumeration of the Ethernet controllers in a blade server is operating-system dependent. You can verify the Ethernet controller designations that a blade server uses through the operating-system settings. The routing of an Ethernet controller to a particular I/O-module bay depends on the type of blade server.
Roadmap. Updating IBM Director If you plan to use IBM Director to manage the blade server, you must check for the latest applicable IBM Director updates and interim fixes. To install the IBM Director updates and any other applicable updates and interim fixes, complete the following steps.
Page 294
JS22 Type 7998: Problem Determination and Service Guide...
Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This information describes where to go for additional information about IBM and IBM products, what to do if you experience a problem with your BladeCenter product or optional device, and whom to call for service, if it is necessary.
The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. IBM maintains pages on the Web where you can get the latest technical information and download device drivers and updates. To access these pages, go to www.ibm.com/jct01004c/systems/support/supportsite.wss/...
Software service and support Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with BladeCenter products. For information about which products are supported by Support Line in your country or region, see www.ibm.com/services/sl/products/.
Page 298
JS22 Type 7998: Problem Determination and Service Guide...
IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Trademarks The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both.
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.
Page 302
(TI) que reciclen responsablemente sus equipos cuando éstos ya no les sean útiles. IBM dispone de una serie de programas y servicios de devolución de productos en varios países, a fin de ayudar a los propietarios de equipos a reciclar sus productos de TI.
States, go to http://www.ibm.com/ibm/environment/products/index.shtml or contact your local waste disposal facility. In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333.
Page 304
For proper collection and treatment, contact your local IBM representative. JS22 Type 7998: Problem Determination and Service Guide...
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards. This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN 55022.
Taiwanese Class A warning statement This is the Taiwanese Class A warning statement. Chinese Class A warning statement View the Chinese Class A warning statement. Japanese Voluntary Control Council for Interference (VCCI) statement View the Japanese VCCI statement. Appendix B. Notices...
Page 308
JS22 Type 7998: Problem Determination and Service Guide...
Page 310
10 configuring 256, 277 Web sites 279 light path LED locations 218 enumeration 278 IBM ServerProven Web site 237 Linux operating system failover 277 IBM Taiwan product service 283 using the reject function 223 redundant network connection 277...
Page 311
Serial Attached SCSI (SAS) drive planning C1001F00 through C1645300 89 removing 246 memory RDIMM 4 C2001000 through C20082FF 99 server firmware IPL status POST C700xxxx 109 C700xxxx 109 about 88 CA000000 through CA2799FF 110 ServerProven Web site, IBM 237 Index...
Page 312
A00-FF0 through A24-xxx 159, 180 SPCN 1xxx codes 17 IBM Director 279 service request numbers (SRNs) System reference codes 16 IBM ServerProven list 237 failing function codes 184 system reliability 238 product recycling 287 service, calling for 232 system-board and chassis assembly...
Page 314
Part Number: 44W2359 Printed in USA (1P) P/N: 44W2359...