Table 12. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
1260
A problem occurred during the
startup of a partition.
The partition could not start at the
Timed Power On setting because the
partition was not set to Normal.
1265
The partition could not start up. An
operating system Main Storage
Dump startup was attempted with
the startup side on D-mode, which is
not a valid operating system startup
scenario. The startup will be halted.
This SRC can occur when a D-mode
SLIC installation fails and attempts a
Main Storage Dump.
1266
The partition could not start up. You
are attempting to start up an
operating system that is not
supported.
1280
A problem occurred during a
partition Main Storage Dump. A
mainstore dump startup did not
complete due to a configuration
mismatch.
1281
A partition memory error occurred.
The failed memory will no longer be
used.
1282
A problem occurred during the
startup of a partition.
1320
A problem occurred during the
startup of a partition.
No default load source was selected.
The startup will attempt to continue,
but there may not be enough
information to find the correct load
source.
1321
A problem occurred during the
startup of a partition.
1322
In the partition startup, code failed
during a check of the load source
path.
2048
A problem occurred during a
partition Main Storage Dump. A
mainstore dump startup did not
complete due to a copy error.
Action
Set the partition to Normal.
Correct the startup settings.
Install a supported operating system and restart the
partition.
Go to "Isolating firmware problems" on page 222.
Restart the partition.
Go to "Isolating firmware problems" on page 222.
Configure a load source for the partition. Then restart the
partition.
Verify that the correct slot is specified for the load source.
Then restart the partition.
Verify that the path for the load source is specified
correctly. Then restart the partition.
Go to "Isolating firmware problems" on page 222.