IBM BladeCenter JS12 Problem Determination And Service Manual page 172

Ibm power6 architecture
Table of Contents

Advertisement

Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
2607-706
2607
2624-xxx
2624
2624-101
2624
2624-102
2624
2624-103
2624
2624-201
cable
network
2624-301
cable
network
2624
2624-701
2624
2624-702
2624
2624-703
2624
2624-704
2624
2624-705
2624
2624-706
2624
2631–xxx
2631
158
JS12 Type 7998: Problem Determination and Service Guide
Description and Action
Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre
Channel adapter card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured
or the system is rebooted. This adapter must be replaced and not brought back
on-line. Failure to adhere to this action could result in data being read or written
incorrectly or in the loss of data.
Generic reference for 4X PCI-E DDR InfiniBand Host Channel Adapter -
system-board and chassis assembly. Go to "Performing the checkout procedure" on
page 187.
Configuration failure - system-board and chassis assembly. Go to "Performing the
checkout procedure" on page 187.
Queue pair create failure - system-board and chassis assembly. Go to "Performing
the checkout procedure" on page 187.
Loop back test failure - system-board and chassis assembly. Go to "Performing the
checkout procedure" on page 187.
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
5. Go to "Performing the checkout procedure" on page 187.
Error Log Analysis indicates that this adapter has failed due to an internal error -
system-board and chassis assembly. Go to "Performing the checkout procedure" on
page 187.
Error Log Analysis indicates that this adapter has failed due to a failure with the
uplink interface used to connect this device to the host processor - system-board and
chassis assembly. Go to "Performing the checkout procedure" on page 187.
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to "Performing the checkout procedure" on
page 187.
Error Log Analysis indicates that this adapter has failed due to a unrecoverable
internal parity error - system-board and chassis assembly. Go to "Performing the
checkout procedure" on page 187.
Error Log Analysis indicates that this adapter has failed due to a internal error -
system-board and chassis assembly. Go to "Performing the checkout procedure" on
page 187.
Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to "Performing the checkout procedure" on
page 187.
Generic reference for IDE controller - system-board and chassis assembly. Go to
"Performing the checkout procedure" on page 187.