Table 12. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
8109
During the startup of a partition, a
failure occurred. The startup will not
continue.
8111
A problem occurred during the
startup of a partition.
8112
During the startup of a partition, a
failure occurred; the startup will not
continue.
8113
During the startup of a partition, an
error occurred while mapping
memory for the partition startup.
8114
During the startup of a partition,
there was a failure verifying the
VPD for the partition resources
during startup.
8115
During the startup of a partition,
there was a low level
partition-to-partition communication
failure.
8117
During the startup of a partition, the
partition did not start up due to a
system firmware error.
8121
During the startup of a partition, the
partition did not start up due to a
system firmware error.
8123
During the startup of a partition, the
partition did not start up due to a
system firmware error.
8125
During the startup of a partition, the
partition did not start up due to a
system firmware error.
8127
During the startup of a partition, the
partition did not start up due to a
system firmware error.
8129
During the startup of a partition, the
partition did not start up due to a
system firmware error.
813A
There was a problem establishing a
console.
8140
Informational system log entry only.
8141
Informational system log entry only.
8142
Informational system log entry only.
8143
Informational system log entry only.
Action
1. Make sure that there is enough memory to start up
the partition.
2. Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
Go to "Isolating firmware problems" on page 222.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.