BladeCenter JS20
Type 8842
Installation and
User's Guide
Welcome. . .
Thank you for buying an
IBM blade server. This blade
server takes advantage of IBM
Power Architecture technologies
and features superior performance,
availability, and scalability.
This
Installation
and User's
contains information for setting up,
configuring, and using
your blade server.
For more information about your
BladeCenter components and
features, you can view the
publications on the
CD or download from the
IBM Support Web site.
Go to http://www.ibm.com/pc/support/.
Guide
Documentation
Before installing the BladeCenter JS20
Type 8842, you should have completed
the following procedures:
• Installed and configured the rack according
to the documentation that came with the rack.
Installed and configured
the BladeCenter unit
into the rack. See the documentation provided
with the BladeCenter unit to install the unit
into the rack.
• Supplied 200 - 240 V ac to the BladeCenter unit.
Install options in the blade server:
• Drives
• Memory modules
• I/O expansion card
See Chapter 7 for more information.
Make sure that the BladeCenter management
module and the Ethernet switch module firmware
support the Serial Over LAN (SOL) feature.
See the
Serial Over LAN Setup Guide
for more information.
Install the blade server in the BladeCenter unit.
See Chapter 3 for more information.
Establish an SOL session with the blade server. See the
Serial Over LAN Setup Guide
for more information.
Install the operating system.
See Chapter 4 for more information.
Install additional applications according to the
instructions provided with the applications.
The blade server is now
ready to use. Be sure to
register and profile your
blade server on the
IBM Support Web site.

Advertisement

Table of Contents
loading

Summary of Contents for IBM eServer BladeCenter JS20 Type 8842

  • Page 1 • Memory modules Thank you for buying an • I/O expansion card See Chapter 7 for more information. IBM blade server. This blade server takes advantage of IBM Power Architecture technologies Make sure that the BladeCenter management module and the Ethernet switch module firmware and features superior performance, support the Serial Over LAN (SOL) feature.
  • Page 2: Server Support

    Check all cables for loose connections and verify that all optional devices you ® installed are on the ServerProven list. You can view the ServerProven list at http://www.ibm.com/pc/compat/ View information about IBM support line at http://www.ibm.com/services/sl/products/ or view support telephone numbers at Problem http://www.ibm.com/planetwide/ solved?
  • Page 3 ERserver BladeCenter JS20 Type 8842 Installation and User’s Guide...
  • Page 4 Note: Before using this information and the product it supports, read the general information in Appendix B, “IBM Statement of Limited Warranty Z125-4753-08 04/2004,” on page 101 and Appendix C, “Notices,” on page 121. Second Edition (September 2004) © Copyright International Business Machines Corporation 2004. All rights reserved.
  • Page 5: Table Of Contents

    Reliability, availability, and serviceability features ... . 27 IBM Director ......28 System-board internal and option connectors .
  • Page 6 ....53 Chapter 9. Updating IBM Director ....55 Chapter 10.
  • Page 7 Industry Canada Class A emission compliance statement ..125 Australia and New Zealand Class A statement ... . 125 United Kingdom telecommunications safety requirement ..125 European Union EMC Directive conformance statement .
  • Page 8 BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 9: Safety

    Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2004...
  • Page 10 IBM Safety Information book. For example, if a caution statement begins with a number 1, translations for that caution statement appear in the IBM Safety Information book under statement 1. Be sure to read all caution and danger statements in this documentation before performing the instructions.
  • Page 11 Statement 1: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet.
  • Page 12 Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
  • Page 13 Statement 3: CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
  • Page 14 The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 15 Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components.
  • Page 16 California de los Estados Unidos está considerado como un causante de cancer y de defectos congénitos, además de otros riesgos reproductivos. Lávese las manos después de usar el producto. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 17: Chapter 1. Introduction

    Note: If you are using a different type of BladeCenter unit instead of the IBM Eserver BladeCenter Type 8677, see the documentation that comes with the BladeCenter unit for more information.
  • Page 18 BladeCenter unit. For more information about determining the power requirements for the blade server, see the IBM Eserver BladeCenter Power Module Upgrade Guidelines Technical Update on the World Wide Web at http://www.ibm.com/pc/support/.
  • Page 19: Related Documentation

    World Wide Web. Related documentation In addition to reviewing the documentation in this library, be sure to review the IBM Eserver BladeCenter Planning and Installation Guide or the IBM Eserver BladeCenter T Planning and Installation Guide for information to help you prepare for system installation and configuration.
  • Page 20: The Ibm Bladecenter Documentation Cd

    IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide: This document contains instructions for establishing a Serial Over LAN (SOL) connection, enabling the SOL feature, and configuring the blade server so that you can run SOL sessions and use the BladeCenter management-module command-line interface.
  • Page 21: Using The Documentation Browser

    Using the Documentation Browser Use the Documentation Browser to browse the contents of the CD, read brief descriptions of the books, and view books using Adobe Acrobat Reader or xpdf. The Documentation Browser automatically detects the regional settings in use in your system and displays the books in the language for that region (if available).
  • Page 22: Notices And Statements Used In This Document

    Notices and statements used in this document The caution and danger statements that appear in this document are also in the multilingual Safety Information document, which is on the IBM BladeCenter Documentation CD. Each statement is numbered for reference to the corresponding statement in the Safety Information document.
  • Page 23: Chapter 2. Preparing The Bladecenter Unit

    I/O bay 1 of the BladeCenter unit. __ d. Configure the BladeCenter unit for SOL operation as described in the IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide. Verify that the firmware code for the BladeCenter unit, management module, and Ethernet switch modules supports the SOL feature.
  • Page 24: Checking The Status Of The Media Tray

    4. If you see 59P6629, have the CIC replaced before installing a BladeCenter JS20 Type 8842 in the BladeCenter unit. To have the CIC replaced, call the IBM Support Center and report the CIC as a failed part and request replacement with the latest CIC field replaceable unit (FRU).
  • Page 25: Chapter 3. Installing The Blade Server In The Bladecenter Unit

    BladeCenter unit. For more information about determining the power requirements for the blade server, see the IBM Eserver BladeCenter Power Module Upgrade Guidelines Technical Update. v To help ensure proper cooling, performance, and system reliability, do not operate the BladeCenter unit for more than 1 minute without a blade server or filler blade installed in each blade bay.
  • Page 26 Do not cover the label that contains the system information. Attach here Important: Do not place the label on the blade server or in any way block the ventilation holes on the blade server. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 27 Configure the BladeCenter unit for Serial Over LAN (SOL) support (see the IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide). b. Turn on the blade server by pressing the power-control button on the blade server control panel.
  • Page 28 BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 29: Chapter 4. Installing The Operating System

    The BladeCenter JS20 Type 8842 has no external USB ports; however, it can communicate with and use the USB diskette drive, CD-ROM drive, and USB port that are in the BladeCenter unit chassis.
  • Page 30 Complete the following steps to download the installation instructions: 1. Go to the IBM Support Web page at http://www.ibm.com/pc/support/. 2. In the Learn section, click Operating system installation. 3. In the For any product section, under Select your product, in the Brand field, select Servers.
  • Page 31: Chapter 5. Configuration Requirements For The Blade Server

    Chapter 5. Configuration requirements for the blade server This chapter contains the configuration tasks that you must perform so that you can run Serial Over LAN (SOL) sessions on the blade server and use the IBM Eserver BladeCenter management-module command-line interface. This chapter also describes other configuration requirements for the blade server.
  • Page 32 Ethernet switch module in I/O bay 1 of the BladeCenter unit. Examples of compatible Ethernet switch modules are the IBM 4-Port Gb Ethernet Switch Module for BladeCenter and the Nortel Networks Layer 2-7 GbE Switch Module for IBM BladeCenter. For more information about...
  • Page 33: Starting The Management And Configuration Program In The Management Module

    Starting the management and configuration program in the management module Use the management-module Web-based management and configuration program for: v Configuring the BladeCenter unit to operate using SOL v Updating and configuring BladeCenter components for SOL operation Complete the following steps to start the Web-based management and configuration program.
  • Page 34: Blade Server Ethernet Controller Enumeration

    Ethernet-controller ports. For device drivers and information about configuring your Ethernet-controller ports, see the Ethernet software documentation that comes with your blade server, or contact your IBM marketing representative or authorized reseller. For updated information about configuring the controllers, go to the IBM Support Web site at http://www.ibm.com/pc/support/.
  • Page 35: Configuring The Blade Server For Fibre Channel Boot

    Fibre Channel switch modules, you must configure the blade server for Fibre Channel boot. Note: The IBM Eserver BladeCenter JS20 Fibre Channel Expansion Card (part number 73P6112) must be installed in the blade server. Complete the following steps to configure the blade server for Fibre Channel boot: 1.
  • Page 36: Updating The Firmware Code For The Blade Server And The Service Processor

    Web site at http://www.ibm.com/pc/support/. If these two types of information match, then the blade server has the latest firmware code. If these two types of information differ, download the latest firmware code from the IBM Support Web site. Follow the update instructions on the IBM Support Web site.
  • Page 37: Updating And Managing The System Flash Using Linux Service Aids

    If you have to recover the system firmware code, see “Recovering the system firmware code” on page 95. v The IBM Remote Deployment Manager (RDM) program does not support the BladeCenter JS20 Type 8842. Chapter 5. Configuration requirements for the blade server...
  • Page 38: Updating And Managing System Flash Using Aix Diagnostics

    Do not power off the system while performing this task! Complete the following steps: 1. Obtain the flash image that you want to update from the IBM Support Web site at http://www.ibm.com/pc/support/. (Look for the flash image for Type 8842, under “AIX Diagnostics Version Number”;...
  • Page 39: Committing The Temporary Firmware Image Using Aix

    temporary file created in the “/var/update_flash_image” directory after the reboot occurs, after you log in to the operating system. Committing the temporary firmware image using AIX After the system reboots successfully and once you are satisfied with the functionality of the new image, commit the update by using the following AIX diagnostic commands: 1.
  • Page 40: Using The Command-Line Interface

    Ethernet switch module that you are using; for example: v IBM 4-Port Gb Ethernet Switch Module for BladeCenter Installation and User’s Guide v Nortel Networks Layer 2-7 GbE Switch Module for IBM BladeCenter Installation Guide BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 41: Chapter 6. Bladecenter Js20 Type 8842 Description

    Chapter 6. BladeCenter JS20 Type 8842 description This chapter contains a detailed description of the BladeCenter JS20 Type 8842. Features and specifications The following table provides a summary of the features and specifications of the BladeCenter JS20 Type 8842. Through the BladeCenter management module, you can view the blade server firmware code and other hardware configuration information.
  • Page 42: What Your Ibm Bladecenter Js20 Type 8842 Offers

    Your blade server is designed to take advantage of advancements in memory management and data storage. Your blade server includes: v IBM Director IBM Director is a workgroup-hardware-management tool that you can use to ® centrally manage xSeries servers. For more information, see the IBM Director documentation on the IBM Director CD.
  • Page 43: Reliability, Availability, And Serviceability Features

    The SOL feature does not require any special client software because it is designed to work with existing standard Telnet consoles. For more information, see the IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide and BladeCenter Management Module Command-Line Interface Reference Guide.
  • Page 44: Ibm Director

    Increased productivity of IT personnel and users v Reduced service and support costs For more information about IBM Director, see the IBM Director CD that comes with the blade server, the IBM Director documentation on the CD, and the IBM xSeries Systems Management Web page at http://www- 1.ibm.com/servers/eserver/xseries/systems_management/xseries_sm.html, which...
  • Page 45: System-Board Internal And Option Connectors

    System-board internal and option connectors The following illustration shows the location of the system-board components, including connectors for user-installable options. Note: The illustrations in this document might differ slightly from your hardware. Chapter 6. BladeCenter JS20 Type 8842 description...
  • Page 46: System-Board Leds

    LED (CR58) Service processor error LED (CR27) NMI error Microprocessor 0 LED (CR17) error LED (CR19) System board error LED (CR20) Temperature Reserved (CR29) error LED (CR16) Light Path Diagnostics (SW1) BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 47: Chapter 7. Installing And Removing Options And Customer-Replaceable Units

    Do not operate the BladeCenter unit for more than 1 minute without a blade server or filler blade installed in each blade bay. v You have followed the reliability guidelines in the documentation that comes with the BladeCenter unit. © Copyright IBM Corp. 2004...
  • Page 48: Handling Static-Sensitive Devices

    Take additional care when handling devices during cold weather. Heating reduces indoor humidity and increases static electricity. v Wear an electrostatic-discharge wrist strap, if one is available. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 49: Removing The Blade Server From The Bladecenter Unit

    Removing the blade server from the BladeCenter unit The following illustration shows how to remove the blade server from the BladeCenter unit. Attention: v To maintain proper system cooling, do not operate the BladeCenter unit for more than 1 minute without a blade server or filler blade installed in each blade bay. v Note the number of the bay that contains the blade server that you will remove.
  • Page 50: Opening The Blade Server Cover

    4. Lift the cover from the blade server and set it aside. Statement 21: CAUTION: Hazardous energy is present when the blade server is connected to the power source. Always replace the blade cover before installing the blade server. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 51: Removing The Blade-Server Bezel Assembly

    Removing the blade-server bezel assembly Before you can replace a defective system-board assembly or blade-server bezel assembly, you must first remove the blade-server bezel assembly. The following illustration shows how to remove the bezel assembly from a blade server. Bezel-assembly release Bezel-assembly release...
  • Page 52 Set the tray aside and remove the four screws. 7. Replace the tray and secure the tray to the system board with screws from the hardware kit. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 53: Installing Memory Modules

    These DIMMs must be compatible with the latest PC2700 SDRAM Registered DIMM PC2700, which is available from http://www.jedec.org/. For a list of supported options for the blade server, go to http://www.ibm.com/pc/us/compat/. v Installing or removing DIMMs changes the configuration information for the blade server.
  • Page 54 7. Touch the static-protective package that contains the DIMM option to any unpainted metal surface on the BladeCenter chassis or any unpainted surface on any other grounded rack component. Then, remove the DIMM from the package. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 55: Installing An I/O Expansion Card

    The Myrinet Cluster Expansion Card for IBM Eserver BladeCenter comes with a cable for connection to the system board of a compatible device. However, the cable is not used in the BladeCenter JS20 Type 8842. Therefore, when you install a Myrinet Cluster Expansion Card for IBM Eserver BladeCenter into a BladeCenter JS20 Type 8842, do not connect the cable from the I/O expansion card to the system board.
  • Page 56 Slide the notch in the narrow end of the card into the raised hook on the tray; then, gently pivot the wide end of the card into the I/O expansion card connectors, as shown in the previous illustration. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 57: Ethernet Controller, Switch Module, And Cabling Requirements

    For more information about installing, configuring, and using the Ethernet switch modules, see the documentation that comes with the Ethernet switch module that you are using, such as the IBM 4-Port Gb Ethernet Switch Module for BladeCenter Installation and User’s Guide or Nortel Networks Layer 2-7 GbE Switch Module for IBM BladeCenter Installation Guide.
  • Page 58: Replacing The Battery

    Replacing the battery IBM has designed this product with your safety in mind. The lithium battery must be handled correctly to avoid possible danger. If you replace the battery, you must adhere to the following instructions. Note: In the U. S., call 1-800-IBM-4333 for information about battery disposal.
  • Page 59 Complete the following steps to replace the battery: 1. Read the safety information beginning on page vii and “Installation guidelines” on page 31. 2. Follow any special handling and installation instructions that come with the battery. 3. If the blade server is operating, shut down the operating system by typing the shutdown -h now command.
  • Page 60 12. Turn on the blade server (see “Turning on the blade server” on page 51). 13. Reset the system date and time through the operating system that you installed. For additional information, see your operating-system documentation. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 61: Replacing The System-Board Assembly

    The blade server does not restart after you recover the system firmware code as described in “Recovering the system firmware code” on page 95. To obtain a new system-board assembly for the blade server, you must call the IBM Support Center to report the original system-board assembly as a failed part. The IBM Support Center team will evaluate the problem and determine whether the blade server requires a replacement system-board assembly or other service.
  • Page 62 You will need this information to complete this step. The replacement system-board assembly comes with a repair identification (RID) tag label. To ensure future entitlement for service, you must write the BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 63 15. Configure an SOL connection and attach it to this blade server. For additional information, see the IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide. 16. The blade server will boot to the open firmware command to enter the serial number of the blade server (with the original system-board assembly).
  • Page 64: Completing The Installation

    Note: If you have just connected the power cords of the BladeCenter unit to electrical outlets, you will have to wait until the power-on LED on the blade server flashes slowly before pressing the power-control button on a blade server. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 65: Installing The Blade-Server Bezel Assembly

    Installing the blade-server bezel assembly The following illustration shows how to install the bezel assembly on the blade server. Bezel-assembly release Bezel-assembly release Control-panel cable Control panel connector Complete the following steps to install the blade-server bezel assembly: 1. Read the safety information beginning on page vii and “Installation guidelines” on page 31.
  • Page 66: Closing The Blade Server Cover

    Therefore, to enable communication between the blade server and these devices, you must perform the configuration tasks that are described in Chapter 5, “Configuration requirements for the blade server,” on page 15 and the IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide.
  • Page 67: Chapter 8. Blade Server Power, Controls, And Indicators

    BladeCenter management module. v If your operating system supports the Wake on LAN feature and it has not been disabled through the BladeCenter management-module Web interface, the Wake on LAN feature can turn on the blade server. © Copyright IBM Corp. 2004...
  • Page 68: Turning Off The Blade Server

    The BladeCenter management-module Web interface can turn off the blade server. Note: After turning off the blade server, wait at least 30 seconds for the hard disk drives to stop spinning before you remove the blade server from the BladeCenter unit. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 69: Blade Server Controls And Leds

    Blade server controls and LEDs This section describes the controls and LEDs on the blade server. Power-control button: This button is behind the control-panel door. Press this button to manually turn the blade server on or off. Note: The power-control button has effect only if local power control is enabled for the blade server.
  • Page 70 BladeCenter management module. v Flashing slowly - The blade server has ac power but is not turned on. v Lit continuously (steady) - The blade server has ac power and is turned on. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 71: Chapter 9. Updating Ibm Director

    Chapter 9. Updating IBM Director If you plan to use IBM Director to manage your blade server, you must check for the latest applicable IBM Director updates and interim fixes. Complete the following steps to install the IBM Director updates and any other applicable updates and interim fixes: 1.
  • Page 72 BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 73: Chapter 10. Solving Problems

    Troubleshooting Guide that comes with the blade server, and the Server Support flowchart in the front of this book. A problem with the BladeCenter JS20 Type 8842 might relate to either the BladeCenter JS20 Type 8842 or the BladeCenter unit.
  • Page 74: System Checkout

    Diagnostic utilities for the Linux operating system Diagnostic utilities for the Linux operating system are available from IBM. For more information, go to http://www- 3.ibm.com/pc/support/site.wss/document.do?lndocid=MIGR-55005. Notes: v For additional information about firmware error codes, location codes, error logs, event logs, and firmware checkpoints, see the BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide.
  • Page 75: Checkpoint Codes

    Checkpoint codes The POST firmware checkpoints (progress codes) indicate the detection of a problem if the server stops on a checkpoint during the startup process. v A four-digit code indicates successful completion of POST when the server does not stop on that checkpoint. v A result other than a four-digit code indicates that POST might have detected a problem.
  • Page 76 Contact a service support representative for assistance. D103 The machine type has been entered. Re-enter a valid machine type. The backspace and delete keys can be used to edit the value entered. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 77 Transfer control to the operating v Perform the system checkout procedure. See system (normal mode startup). “System checkout” on page 58. v See BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide. E10A Load the RTAS device tree. 1. Perform the system checkout procedure. See “System checkout”...
  • Page 78 1. Perform the system checkout procedure. See “System checkout” on page 58. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 79 Contact a service support representative for more information. E14D Load the startup image. See the BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide. E150 Create the host (primary) PCI 1. Perform the system checkout procedure. See controller node.
  • Page 80 2. Make sure that the network connections are correct; then, retry the operation. 3. If there are no problems with the BOOTP server or the network connection, replace the system-board assembly. Contact a service support representative for assistance. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 81 Checkpoint code Description Suggested action E177 Transfer failure due to a TFTP error 1. Make sure that the BOOTP server is correctly condition. configured; then, retry the operation. 2. Make sure that the network connections are correct; then, retry the operation. 3.
  • Page 82 1. Perform the system checkout procedure. See service-mode boot list. “System checkout” on page 58. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 83 Checkpoint code Description Suggested action E1AC System startup using the customized 1. Perform the system checkout procedure. See service-mode boot list. “System checkout” on page 58. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information.
  • Page 84 2. This error indicates that you might have a problem scanned is also displayed. with the system board. Contact a service support representative for more information. E1FA Reserved Have the blade server serviced. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 85 2. If a later firmware version is not available, or if the problem remains after you update the firmware code, go to the “Boot problem resolution” section in the BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide. Follow the instructions in that section.
  • Page 86 1. Perform the system checkout procedure. See “System checkout” on page 58. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 87 Checkpoint code Description Suggested action E210 Load and relocate the hardware 1. Perform the system checkout procedure. See isolation layer (HIL). “System checkout” on page 58. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information.
  • Page 88 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. E2B0 Reserved No action is required. E2B1 Reserved No action is required. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 89 Checkpoint code Description Suggested action E440 Validate NVRAM and initialize 1. Perform the system checkout procedure. See partitions as needed. “System checkout” on page 58. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information.
  • Page 90 1. Perform the system checkout procedure. See “System checkout” on page 58. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 91: Firmware Error Codes

    Notes: v When you are solving a problem with the BladeCenter JS20 Type 8842 blade server, you must determine whether the problem is in the BladeCenter JS20 Type 8842 blade server or in the BladeCenter unit.
  • Page 92 2. Replace the system-board assembly. Contact a service support representative for more information. 20D00011 The run-time extraction services Perform the system checkout procedure. See “System (RTAS) program attempt to allocate checkout” on page 58. memory failed. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 93 58. 20D10010 Stack underflow from the Fibre 1. Check the http://www.ibm.com/pc/support/ Web site for Channel adapter. microcode updates for the Fibre Channel adapter. Apply the latest update, if one is available. 2. If an update is not available, contact a system administrator for assistance.
  • Page 94 Apply the latest updates, if they are available. 3. If updates are not available, contact your system administrator for assistance. If the problem remains, call for service. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 95 21020010 The USB CD-ROM drive remained 1. Retry the operation. busy longer than the amount of 2. Check the http://www.ibm.com/pc/support/ Web site for allocated time. firmware updates for the management module, service processor, and blade server. Apply the latest updates, if they are available.
  • Page 96 22001001 PCI Ethernet adapter failure. Replace the adapter. 22001002 PCI Ethernet adapter failure. Replace the adapter. 22010001 PCI Ethernet adapter failure. Replace the adapter. 22011001 PCI Ethernet adapter failure. Replace the adapter. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 97 If the location code identifies a slot: 1. Reseat the adapter and restart the blade server. 2. Replace the adapter. 3. Check the http://www.ibm.com/pc/support/ Web site for system firmware updates. Apply the latest update, if one is available. 4. If an update is not available, contact a system administrator for assistance.
  • Page 98 Note: After you replace the battery, you must reset the system date and time through the operating system that you installed. If the problem still remains, replace the system-board assembly. Contact a service support representative for assistance. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 99 Table 2. Abbreviated list of firmware error codes (continued) Error code Failing device or problem found Suggested action 25A80210 Setenv/$Setenv parameter error; If the problem remains, replace the battery in the blade name contains a null character. server. For additional information, see “Replacing the battery”...
  • Page 100 DIMM4 unsupported DIMM3 and DIMM4 unsupported DIMM3 failed and DIMM4 unsupported DIMM3 missing and DIMM4 failed DIMM4 failed DIMM4 failed and DIMM3 unsupported DIMM3 and DIMM4 failed DIMM3 and DIMM4 mismatch BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 101 Table 2. Abbreviated list of firmware error codes (continued) Error code Failing device or problem found Suggested action 25C0xx yy DIMM failure (continued): Note: For additional information about DIMMs, see (continued) “Installing memory modules” on page 37. where xx and yy are: 1.
  • Page 102 3. If the problem remains, replace the blade server. Contact a service support representative for assistance. 2B208888 Operating-system termination request This is an informational message. No action is required. has been received. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 103 7 - Program interrupt (SRI) 8 - Floating unavailable interrupt (FUI) Complete the following steps: 1. Check the http://www.ibm.com/pc/support/ Web site for system firmware updates. Apply the latest update, if one is available. 2. If an update is not available, contact a system administrator for assistance.
  • Page 104: Troubleshooting Charts

    Eserver BladeCenter HS20 Type 8678 Hardware Maintenance Manual and Troubleshooting Guide for more information. v If you have problems with an Ethernet or Fibre Channel switch module, IBM Eserver BladeCenter Optical Pass-Thru Module, I/O adapter, or other optional...
  • Page 105: Power Problems

    Power problems Power symptom Suggested action The blade server does not 1. Make sure that: turn on. a. The power-on LED on the front of the BladeCenter unit is lit. b. The LEDs on all the BladeCenter power modules are lit. c.
  • Page 106: Network Connection Problems

    The following documentation: – BladeCenter Type 8677 Hardware Maintenance Manual and Troubleshooting Guide – The IBM Eserver BladeCenter and BladeCenter T Serial Over LAN Setup Guide Note: For the latest editions of the IBM BladeCenter documentation, go to http://www.ibm.com/pc/support/ on the World Wide Web.
  • Page 107: Service Processor Problems

    Service processor problems Service processor symptom Suggested action Service processor reports a 1. If the blade server is operating, shut down the operating system. general monitor failure. 2. If the blade server was not turned off, press the power-control button (behind the blade-server control-panel door) to turn off the server.
  • Page 108: Light Path Diagnostics Table

    LED (CR58) Service processor error LED (CR27) NMI error Microprocessor 0 LED (CR17) error LED (CR19) System board error LED (CR20) Temperature Reserved (CR29) error LED (CR16) Light Path Diagnostics (SW1) BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 109 Table 3. Light path diagnostics Lit blade-error Cause Action None An error has occurred and cannot be isolated, An error has occurred that is not represented or the service processor has failed. by a light path diagnostics LED. Check the system event log in the BladeCenter management module for more information about the error.
  • Page 110 BladeCenter unit, and then restart the server. 2. If the LED stays lit, replace the system-board assembly. Contact a service support representative for assistance. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 111: Recovering The System Firmware Code

    RAS functions as outlined in the Linux on pSeries RAS White paper available from http://techsupport.services.ibm.com/server/Linux_on_pSeries/images/Linux_RAS.pdf. These functions include first failure data capture and error log analysis. With the toolkit installed, problem determination and correction is greatly enhanced and the likelihood of an extended system outage is reduced.
  • Page 112: Recovering The Temp Image From The Perm Image

    6. If you moved jumper J14, complete the following steps: a. Turn off the blade server. b. Remove the blade server (see “Removing the blade server from the BladeCenter unit” on page 33). BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 113 Update the flash again, if you are updating the system firmware code. You might need to update the firmware code to the latest version. See http://www.ibm/.com/pc/support for more information about how to update the firmware code. Chapter 10. Solving problems...
  • Page 114 BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 115: Appendix A. Getting Help And Technical Assistance

    If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your Eserver system, and whom to call for service, if it is necessary.
  • Page 116: Getting Help And Information From The World Wide Web

    Getting help and information from the World Wide Web On the World Wide Web, the IBM Web site has up-to-date information about IBM Eserver, xSeries, and IntelliStation products, services, and support. The address for IBM Eserver and xSeries information is http://www.ibm.com/eserver/xseries/.
  • Page 117: Appendix B. Ibm Statement Of Limited Warranty Z125-4753-08 04/2004

    Country-unique Terms, and Part 3 - Warranty Information. The terms of Part 2 replace or modify those of Part 1. The warranties provided by IBM in this Statement of Limited Warranty apply only to Machines you purchase for your use, and not for resale.
  • Page 118 If the Machine does not function as warranted during the warranty period, contact IBM or your reseller to obtain warranty service. If you do not register the Machine with IBM, you may be required to present proof of purchase as evidence of your entitlement to warranty service.
  • Page 119 Personal Data. Limitation of Liability IBM is responsible for loss of, or damage to, your Machine only while it is 1) in IBM’s possession or 2) in transit in those cases where IBM is responsible for the transportation charges.
  • Page 120: Part 2 - Country-Unique Terms

    TO YOU. Governing Law Both you and IBM consent to the application of the laws of the country in which you acquired the Machine to govern, interpret, and enforce all of your and IBM’s rights, duties, and obligations arising from, or relating in any manner to, the subject matter of this Statement of Limited Warranty, without regard to conflict of law principles.
  • Page 121 Limitation of Liability: The following is added at the end of this section: In accordance with Article 1328 of the Peruvian Civil Code the limitations and exclusions specified in this section will not apply to damages caused by IBM’s willful misconduct (“dolo”) or gross negligence (“culpa inexcusable”).
  • Page 122 Limitation of Liability: The following is added to this section: Where IBM is in breach of a condition or warranty implied by the Trade Practices Act 1974 or other similar legislation, IBM’s liability is limited to the repair or replacement of the goods or the supply of equivalent goods.
  • Page 123 2. as to any other actual damage arising in any situation involving nonperformance by IBM pursuant to, or in any way related to the subject of this Statement of Limited Warranty, the charge paid by you for the individual Machine that is the subject of the claim.
  • Page 124 Consumer Guarantees Act 1993 or other legislation which cannot be excluded or limited. The Consumer Guarantees Act 1993 will not apply in respect of any goods which IBM provides, if you require the goods for the purposes of a business as defined in that Act.
  • Page 125 Machine in any of those countries from either (1) an IBM reseller approved to perform warranty service or (2) from IBM, provided the Machine has been announced and made available by IBM in the country in which you wish to obtain service.
  • Page 126 Directorates of Istanbul, the Republic of Turkey; 8) in each of the following specified countries, any legal claim arising out of this Statement of Limited Warranty will be brought before, and settled exclusively by, the competent court of a) Athens for BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 127 598 (2) of the Austrian Code of Civil Procedure, the parties expressly waive the application of paragraph 595 (1) figure 7 of the Code. IBM may, however, institute proceedings in a competent court in the country of installation.
  • Page 128 Except as otherwise provided by mandatory law: 1. IBM’s liability for any damages and losses that may arise as a consequence of the fulfillment of its obligations under or in connection with this Statement of Limited Warranty or due to any other cause related to this Statement of Limited...
  • Page 129 The limitation period for consumers in action for breach of warranty is the statutory period as a minimum. In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded.
  • Page 130 The minimum warranty period for Machines is twelve months. In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded.
  • Page 131 For the purposes of this section, a “Default” means any act, statement, omission, or negligence on the part of IBM in connection with, or in relation to, the subject matter of this Statement of Limited Warranty in respect of which IBM is legally liable to you, whether in contract or tort.
  • Page 132 For the purposes of this section, a “Default” means any act, statement, omission, or negligence on the part of IBM in connection with, or in relation to, the subject matter of this Statement of Limited Warranty in respect of which IBM is legally liable to you, whether in contract or tort.
  • Page 133: Part 3 - Warranty Information

    Note: “Region” means either Hong Kong or Macau Special Administrative Region of China. A warranty period of 3 years on parts and 1 year on labor means that IBM provides warranty service without charge for: 1. parts and labor during the first year of the warranty period; and 2.
  • Page 134 This type of Warranty Service is a combination of Type 1 and Type 4 (see above). When a 5, 6 or 7 type of warranty service is listed, IBM will determine which type of warranty service is appropriate for the repair.
  • Page 135 Phone numbers are subject to change without notice. For the warranty service contact telephone number in a country subsequently added to the EU and not yet reflected in the list below, contact IBM in that country or visit the website above for a current telephone listing.
  • Page 136 BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 137: Appendix C. Notices

    Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
  • Page 138: Trademarks

    Red Hat, the Red Hat “Shadow Man” logo, and all Red Hat-based trademarks and logos are trademarks or registered trademarks of Red Hat, Inc., in the United States and other countries. Other company, product, or service names may be trademarks or service marks of others. BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 139: Important Notes

    IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
  • Page 140: Battery Return Program

    In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333.
  • Page 141: Industry Canada Class A Emission Compliance Statement

    IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards. This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN 55022.
  • Page 142: Taiwanese Class A Warning Statement

    Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference (VCCI) statement BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 143: Power Cords

    Power cords For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet. IBM power cords used in the United States and Canada are listed by Underwriter’s Laboratories (UL) and certified by the Canadian Standards Association (CSA).
  • Page 144 Colombia, Costa Rica, Cuba, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Mexico, Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 145: Index

    59 removing 46 POST 75 system board 29 error log configuration entries 54 automatic 15 location code 57 command-line interface 24 error messages. Ethernet controller 17, 18 See error codes Fibre Channel boot 19 © Copyright IBM Corp. 2004...
  • Page 146 Web site 58 installing 39 ppc64 utilities 14 location 40 service aids for hardware diagnostics 95 network-interface requirements 39 updating the system flash 21 IBM Director 26, 28, 55 using the reject function 96 BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 147 Linux operating system (continued) option (continued) verifying the system firmware levels 21 memory modules 37 location code 57 problems 90 logging onto the management module 17 order of installation IDE hard disk drives 36 memory modules 38 system-board components 46 ordering management-module Web interface 17 documentation 99...
  • Page 148 51 United States electronic emission Class A notice 124 United States FCC Class A notice 124 update packages, installing 13 Update_Flash command 95 updating firmware blade server 20 BladeCenter JS20 Type 8842: Installation and User’s Guide...
  • Page 150 Part Number: 25K8416 Printed in USA (1P) P/N: 25K8416...