Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
2604-705
2604
2604-706
2604
2607-xxx
2607
2607-102
2607
2607-103
2607
2607-104
2607
2607-105
2607
2607-106
2607
2607-108
2607 221
2607-110
2607
2607-201
2607 221
2607-203
2607
2607-204
2607 221
2607-205
2607 221
2607-701
2607
2607-703
2607
2607-704
2607
2607-705
2607
Description and Action
Error Log Analysis indicates that a parity error has been detected for the Fibre
Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data
being read or written incorrectly.
Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre
Channel adapter card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured
or the system is rebooted. This adapter must be replaced and not brought back
on-line. Failure to adhere to this action could result in data being read or written
incorrectly or in the loss of data.
Generic reference for 8Gb PCIe Fibre Channel Expansion Card. Go to "Performing
the checkout procedure" on page 187.
Reset Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
Register Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
SRAM Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
Internal Wrap Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe
Fibre Channel Expansion Card.
Gigabit Link Module (GLM) Wrap Test failure for the Fibre Channel adapter card.
Replace the 8Gb PCIe Fibre Channel Expansion Card.
Enhanced Error Handling Failure on the bus for the Fibre Channel adapter card. Go
to "Performing the checkout procedure" on page 187.
Enhanced Error Handling Failure on the Fibre Channel adapter card. Replace the
8Gb PCIe Fibre Channel Expansion Card.
Configuration Register Test Failure for the Fibre Channel adapter card. Go to
"Performing the checkout procedure" on page 187.
PCI Wrap Test Failure for the Fibre Channel adapter card. Replace the 8Gb PCIe
Fibre Channel Expansion Card.
DMA Test Failure for the Fibre Channel adapter card. Go to "Performing the
checkout procedure" on page 187.
Error on Read/Write Operation for the Fibre Channel adapter card. Go to
"Performing the checkout procedure" on page 187.
Error Log Analysis indicates that the adapter self-test failed for the Fibre Channel
adapter card. Go to "Performing the checkout procedure" on page 187.
Error Log Analysis indicates that an unknown adapter error has occurred for the
Fibre Channel adapter card. Go to "Performing the checkout procedure" on page
187.
Error Log Analysis indicates that an adapter error has occurred for the Fibre Channel
adapter card. Go to "Performing the checkout procedure" on page 187.
Error Log Analysis indicates that a parity error has been detected for the Fibre
Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data
being read or written incorrectly.