IBM BladeCenter JS12 Problem Determination And Service Manual page 94

Ibm power6 architecture
Table of Contents

Advertisement

Table 14. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Error code
BA210011
BA210012
BA210013
BA210020
BA210100
80
JS12 Type 7998: Problem Determination and Service Guide
Description
The transfer of control to the IO
Reporter failed
There was an NVRAMRC forced-boot
problem; unable to load the previous
boot's operating system image
There was a partition firmware error
when in the SMS menus.
I/O configuration exceeded the
maximum size allowed by partition
firmware.
An error may not have been sent to the
management module event log.
Action
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
1. Use the SMS menus to verify that the
partition firmware can still detect the
operating system image.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.
1. Increase the logical memory block size to
256 MB and restart the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.