Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
A05-21x
A05-22x
A05-24x
A0D-00x
A0D-06x
A0D-07x
A0D-08x
166
JS12 Type 7998: Problem Determination and Service Guide
Description
System shutdown due to Over
temperature condition.
System shutdown due to over
temperature and fan failure.
Power Fault specifically due to internal
battery failure.
Error log analysis indicates an error
detected by the Service Processor, but
the failure could not be isolated.
Service Processor reports unknown
communication error.
Internal service processor firmware
error or incorrect version.
Other internal Service Processor
hardware error.
FRU/action
1. Make sure that:
a. The room ambient temperature is within
the system operating environment.
b. There is unrestricted air flow around the
system.
c. All system covers are closed.
d. There are no fan failures
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
3. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.

Advertisement

Table of Contents
loading

Table of Contents