IBM BladeCenter JS12 Problem Determination And Service Manual page 195

Ibm power6 architecture
Table of Contents

Advertisement

Table 26. ssss-102 through ssss-640 SRNs (continued)
SRN
FFC
ssss-108
ssss
ssss-110
ssss
ssss-112
ssss
ssss-114
ssss
ssss-116
ssss
ssss-117
ssss
ssss-118
ssss 252B
ssss-120
ssss
Description and action
The bus test failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
The media format is corrupted.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
The diagnostic test failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
An unrecoverable hardware error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
A protocol error.
1. Make sure that the device, adapter and diagnostic firmware, and the application
software levels are compatible.
2. If you do not find a problem, call your operating-system support person.
A write-protect error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
A SCSI command time-out occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
A SCSI busy or command error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
181
Chapter 2. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents