Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
A02-06x
A02-09x
A02-10x
A02-11x
A02-12x
A02-13x
A03-00x
A03-01x
162
JS12 Type 7998: Problem Determination and Service Guide
Description
Memory Data error (Bad data going to
memory).
System bus parity error.
System bus time-out error.
System bus protocol/transfer error.
I/O Host Bridge time-out error.
I/O Host Bridge address/data parity
error.
Error log analysis indicates an error
detected by the I/O device, but the
failure could not be isolated.
I/O Bus Address parity error.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see"POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.