B200xxxx Logical partition SRCs

A B200xxxx system reference code (SRC) is an error code that is related to logical
partitioning.
Table 12 describes error codes that might be displayed if POST detects a problem.
The description also includes suggested actions to correct the problem.
Note: For problems persisting after completing the suggested actions, see
"Checkout procedure" on page 186 and "Solving undetermined problems" on page
231.
Table 12. B200xxxx Logical partition SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
1130
A problem occurred during the
migration of a partition
You attempted to migrate a partition
to a system that has a power or
thermal problem. The migration will
not continue.
1131
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1132
A problem occurred during the
startup of a partition.
A platform firmware error occurred
while it was trying to allocate
memory. The startup will not
continue.
1133
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1134
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1140
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
Action
Look for and fix power or thermal problems and then
retry the migration.
Check for server firmware updates; then, install the
updates if available.
Collect a platform dump and then go to "Isolating
firmware problems" on page 222.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.