Table 17. B7xxyyy Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
F10C
F120
F130

BA000010 to BA400002 Partition firmware SRCs

The power-on self-test (POST) might display an error code that the partition firmware detects. Try to
correct the problem with the suggested action.
Table 18 describes error codes that might be displayed if POST detects a problem. The description also
includes suggested actions to correct the problem.
Note: For problems persisting after completing the suggested actions, see "Checkout procedure" on page
176 and "Solving undetermined problems" on page 223.
Table 18. BA000010 to BA400002 Partition firmware SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
BA000010
BA000020
BA000030
BA000031
Description
The platform LIC detected an internal
problem performing Partition Mobility.
Informational system log entry only.
Thermal Power Management Device
firmware error was detected.
Description
The device data structure is corrupted
Incompatible firmware levels were
found
An lpevent communication failure
occurred
An lpevent communication failure
occurred
Action
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 216.
No corrective action is required.
Check for server firmware updates; then,
install the updates if available.
Action
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
Chapter 2. Diagnostics
61