6Xxxyyyy Srcs - IBM BladeCenter JS12 Problem Determination And Service Manual

Ibm power6 architecture
Table of Contents

Advertisement

Table 5. 1xxxyyyy SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Description
Error Codes
8423
No processor VPD was found
84A0
No backplane VPD was found 1. Go to "Checkout procedure" on page 186.

6xxxyyyy SRCs

The 6xxxyyyy system reference codes are virtual optical reference codes.
Look for the rightmost 4 characters (yyyy in 6xxxyyyy) in the error code; this is the
reference code. Find the reference code in Table 6.
Table 6. 6xxxyyyy SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Description
Error Codes
632Byyyy codes are Network File System (NFS) virtual optical SRCs
632BCFC1
A virtual optical device cannot
access the file containing the
list of volumes.
632BCFC2
A non-recoverable error was
detected while reading the list
of volumes.
632BCFC3
The data in the list of volumes
is not valid.
632BCFC4
A virtual optical device cannot
access the file containing the
specified optical volume.
632BCFC5
A non-recoverable error was
detected while reading a
virtual optical volume.
632BCFC6
The file specified does not
contain data that can be
processed as a virtual optical
volume.
22
JS12 Type 7998: Problem Determination and Service Guide
Action
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on
page 274.
2. Replace the system-board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on
page 274.
Action
On this partition and on the Network File System server, verify
that the proper file is specified and that the proper authority is
granted.
Resolve any errors on the Network File System server.
On the Network File System server, verify that the proper file is
specified, that all files are entered correctly, that there are no blank
lines, and that the character set used is valid.
On the Network File System server, verify that the proper file is
specified in the list of volumes, and that the proper authority is
granted.
Resolve any errors on the Network File System server.
On the Network File System server, verify that all the files specified
in the list of optical volumes are correct.

Advertisement