Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
A12-16x
A12-50x
A13-00x
A13-01x
A13-02x
A13-03x
A13-04x
A13-05x
172
JS12 Type 7998: Problem Determination and Service Guide
Description
A non-critical error has been detected, a
system bus internal hardware/switch
error.
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
A non-critical error has been detected, a
error log analysis indicates an error
detected by the I/O device, but the
failure could not be isolated.
A non-critical error has been detected,
an I/O bus address parity error.
A non-critical error has been detected,
an I/O bus data parity error.
A non-critical error has been detected,
an I/O bus time-out, access or other
error.
A non-critical error has been detected,
an I/O bridge/device internal error.
A non-critical error has been detected,
an I/O error on non-PCI bus.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2. Check the BladeCenter management-module
event log for an entry around this time. If no
entry is found, replace the system-board and
chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.