Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
651-613
D01
651-614
214
651-615
292
651-619
651-621
2C6
651-623
2C6
651-624
214
651-625
214
651-626
214
651-627
214
651-628
210
651-629
210
651-632
308
651-639
210
651-640
2D5
651-641
2D6
651-642
2D3
651-643
2D3
651-644
2D3
651-659
2CD
651-65A
2CE
651-65B
2CC
651-664
302
651-665
303
651-666
304
651-669
2CD
Description and Action
External cache ECC single-bit error. Go to "Performing the checkout procedure" on
page 187.
System bus time-out error. Go to "Performing the checkout procedure" on page 187.
Time-out error waiting for I/O. Go to "Performing the checkout procedure" on page
187.
Error log analysis indicates an error detected by the CPU. Use failing function codes
and the physical location codes from the diagnostic problem report screen to
determine the FRUs.
ECC correctable error. Go to "Performing the checkout procedure" on page 187.
Correctable error threshold exceeded. Go to "Performing the checkout procedure" on
page 187.
Memory control subsystem internal error. Go to "Performing the checkout
procedure" on page 187.
Memory address error (invalid address or access attempt). Go to "Performing the
checkout procedure" on page 187.
Memory data error (bad data going to memory). Go to "Performing the checkout
procedure" on page 187.
System bus time-out error. Go to "Performing the checkout procedure" on page 187.
System bus protocol/transfer error. Go to "Performing the checkout procedure" on
page 187.
Error log analysis indicates an error detected by the memory controller. Go to
"Performing the checkout procedure" on page 187.
Internal device error. Go to "Performing the checkout procedure" on page 187.
Error log analysis indicates an error detected by the I/O. Using the problem
determination procedure, failing function codes, and the physical location codes
from the diagnostic problem report to determine the FRUs.
I/O general bus error. Go to "Performing the checkout procedure" on page 187.
Secondary I/O general bus error. Go to "Performing the checkout procedure" on
page 187.
Internal service processor memory error. Go to "Performing the checkout procedure"
on page 187.
Internal service processor firmware error. Go to "Performing the checkout
procedure" on page 187.
Other internal service processor hardware error. Go to "Performing the checkout
procedure" on page 187.
ECC correctable error. Go to "Performing the checkout procedure" on page 187.
ECC correctable error. Go to "Performing the checkout procedure" on page 187.
ECC correctable error. Go to "Performing the checkout procedure" on page 187.
Correctable error threshold exceeded. Go to "Performing the checkout procedure" on
page 187.
Correctable error threshold exceeded. Go to "Performing the checkout procedure" on
page 187.
Correctable error threshold exceeded. Go to "Performing the checkout procedure" on
page 187.
Correctable error threshold exceeded. Go to "Performing the checkout procedure" on
page 187.