Advertisement

Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
A1D-34x
A non-critical error has been detected:
Wire Test Error.
A1D-35x
A non-critical error has been detected:
Mainstore or Cache IPL Diagnostic
Error.
A1D-37x
A non-critical error has been detected:
Clock or PLL Error.
A1D-38x
A non-critical error has been detected:
Hardware Scan or Initialization Error.
A1D-40x
A non-critical error has been detected:
Presence/Detect Error (Mis-Plugged).
A1D-50x
Recoverable errors on resource indicate
a trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The
system is operating with the potential
for an unrecoverable error.
A24-000
Spurious interrupts on shared interrupt
level have exceeded threshold
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. If no entry is found, replace the system-board
and chassis assembly.
1. If repair is not immediately available, reboot
and the resource will be deconfigured;
operations can continue in a degraded mode.
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
3. If no entry is found, replace the system-board
and chassis assembly.
1. Check the BladeCenter management-module
event log. If an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. Replace part numbers reported by the
diagnostic program.
3. If no entry is found, replace the system-board
and chassis assembly.
Chapter 2. Diagnostics