Ssss-102 Through Ssss-640 Srns For Scsi Devices - IBM BladeCenter JS12 Problem Determination And Service Manual

Ibm power6 architecture
Table of Contents

Advertisement

Table 25. A00-FF0 through A24-xxx SRNs (continued)
SRN
A24-xxx

ssss-102 through ssss-640 SRNs for SCSI devices

These service request numbers (SRNs) identify a SCSI device problem.
Use Table 26 to identify an SRN when you suspect a SCSI device problem. Replace
the parts in the order that the failing function codes (FFCs) are listed.
Notes:
1. Some SRNs might have 4 digits rather than 3 digits after the dash (–).
2. The ssss before the dash (–) represents the 3 digit or 4 digit SCSI SRN.
Table 26. ssss-102 through ssss-640 SRNs
SRN
FFC
ssss-102
ssss
ssss-104
ssss
ssss-105
ssss
ssss-106
ssss
180
JS12 Type 7998: Problem Determination and Service Guide
Description
Spurious interrupts have exceeded
threshold.
Description and action
An unrecoverable media error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
The motor failed to restart.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
The drive did not become ready.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
The electronics card test failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly" on page 274.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 88.
2. Replace part numbers reported by the
diagnostic program.
3. If no entry is found, replace the system-board
and chassis assembly.

Advertisement

Table of Contents
loading