Location Codes - IBM BladeCenter JS12 Problem Determination And Service Manual

Ibm power6 architecture
Table of Contents

Advertisement

v Collect an AIX dump from the /var/adm/platform directory.
v Collect a Linux dump from the /var/log/dump directory.
v Collect an Integrated Virtualization Manager (IVM) dump from the

Location codes

Location codes identify components of the blade server. Location codes are
displayed with some error codes to identify the blade server component that is
causing the error.
See "System-board connectors" on page 9 for component locations.
Notes:
1. Location codes do not indicate the location of the blade server within the
2. For checkpoints with no associated location code, see "Light path diagnostics"
3. For checkpoints with location codes, use the following table to identify the
4. For 8-digit codes not listed in Table 2, see "Checkout procedure" on page 186.
Table 2. Location codes
Location code
Un location codes are for enclosure and VPD locations.
Un = Utttt.mmm.sssssss
tttt = system machine type
mmm = system model number
sssssss = system serial number
Un-P1
Un-P1-C1
Un-P1-C2
Un-P1-C3
Un-P1-C4
Un-P1-C5
Un-P1-C6
Un-P1-C7
Un-P1-C8
Un-P1-C9
Un-P1-C10
Un-P1-C11
Un-P1-D1
Un-P1-D2
Un-P1-E1
14
JS12 Type 7998: Problem Determination and Service Guide
IVM-managed JS12 blade server through the Manage Dumps task in the IVM
console.
BladeCenter unit. The codes identify components of the blade server only.
on page 218 to identify the failing component when there is a hang condition.
failing component when there is a hang condition.
Component
System-board and chassis assembly (Planar, FSP, SPCN,
CP0, P5IOC2)
DIMM 1 (DIMM1A)
DIMM 2 (DIMM1B)
DIMM 3 (DIMM0A)
DIMM 4 (DIMM0B)
DIMM 5 (DIMM3B)
DIMM 6 (DIMM3A)
DIMM 7 (DIMM2B)
DIMM 8 (DIMM2A)
Management card (MGMT CRD)
PCI-X expansion card (PIOCARD)
PCIe high-speed expansion card (PIOCARD)
Front SAS hard disk drive (SFF0)
Rear SAS hard disk drive (SFF1)
Battery (BATT)

Advertisement

Table of Contents
loading