A00-FF0 through A24-xxx SRNs

AIX might generate service request numbers (SRNs) from A00-FF0 to A24-xxx.
Description and Action
IDE disk diagnostic failure. Go to "Performing the checkout procedure" on page 187.
IDE disk error on open or configuring device system-board and chassis assembly -
IDE controller. Go to "Performing the checkout procedure" on page 187.
Physical volume hardware error. Go to "Performing the checkout procedure" on
page 187.
Smart status threshold exceeded. Go to "Performing the checkout procedure" on
page 187.
Command timeouts threshold exceeded. Go to "Performing the checkout procedure"
on page 187.
Command timeout with error condition. Go to "Performing the checkout procedure"
on page 187.
Hardware command or DMA failure. Go to "Performing the checkout procedure" on
page 187.
IDE DMA error with no error status. Go to "Performing the checkout procedure" on
page 187.
Timeout waiting for controller or drive with no busy status. Go to "Performing the
checkout procedure" on page 187.
Generic reference for USB controller/adapter - system-board and chassis assembly.
Go to "Performing the checkout procedure" on page 187.
Temporary device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Go to "Performing the checkout procedure" on page 187.
Temporary device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Go to "Performing the checkout procedure" on page 187.
159