Table 23. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
103-151
151
109-200
110-101
110-921 to
812 xxx
110-926
110-935
812
110-xxxx
xxxx 221
111-107
111-108
111-121
111-78C
227
111-999
210
650-xxx
650
651-xxx
Description and Action
The time-of-day battery failed.
1. Go to "Removing the battery" on page 267 to start the battery replacement
procedure.
2. Go to "Installing the battery" on page 268 to complete the procedure.
The system crashed while you running it.
1. Go to "Performing the checkout procedure" on page 187.
2. If the 8-digit error and location codes were NOT reported, run AIX diagnostics in
problem determination procedure and record and report the 8-digit error and
location codes for this SRN.
The diagnostics did not detect an installed resource. If this SRN appeared when
running concurrent diagnostics, then run concurrent diagnostics using the diag -a
command.
The system halted while diagnostics were executing.
Go to "Performing the checkout procedure" on page 187 or problem resolution.
Note: xxx corresponds to the last three digits of the SRN.
The system halted while diagnostics were executing. Use the problem determination
procedure.
The system halted while diagnostics were executing.
Note: xxxx corresponds to the last three or four digits of the SRN following the dash
(-).
1. If your 110 SRN is not listed, substitute the last three or four digits of the SRN
for xxxx and go to "Failing function codes 151 through 2D02" on page 184 to
identify the failing feature.
2. Run stand-alone diagnostics and the problem determination procedure for your
operating system.
A machine check occurred. Go to "Performing the checkout procedure" on page 187.
An encoded SRN was displayed. Go to "Performing the checkout procedure" on
page 187.
There is a display problem. Go to "Performing the checkout procedure" on page 187.
PCI adapter I/O bus problem. Go to "Performing the checkout procedure" on page
187. Perform "Solving undetermined problems" on page 231.
System does not perform a soft reset. Go to "Performing the checkout procedure" on
page 187.
Disk drive configuration failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 88.
2. Replace any parts reported by the diagnostic program.
3. Update the disk drive firmware.
4. Troubleshoot the disk drive.
5. Replace the system-board and chassis assembly.
The CEC reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
143