IBM BladeCenter JS12 Problem Determination And Service Manual page 44

Ibm power6 architecture
Table of Contents

Advertisement

Table 12. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
1141
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1142
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1143
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1144
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1148
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1150
During the startup of a partition, a
partitioning configuration problem
occurred.
1151
A problem occurred during the
migration of a partition.
The migration of a partition did not
complete.
1170
During the startup of a partition, a
failure occurred due to a validation
error.
1225
A problem occurred during the
startup of a partition.
The partition attempted to start up
prior to the platform fully
initializing. Restart the partition after
the platform has fully completed and
the platform is not in standby mode.
1230
During the startup of a partition, a
partitioning configuration problem
occurred; the partition is lacking the
necessary resources to start up.
30
JS12 Type 7998: Problem Determination and Service Guide
Action
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Go to "Verifying the partition configuration" on page 189.
Check for server firmware updates; then, install the
updates if available.
Go to "Verifying the partition configuration" on page 189.
Restart the partition.
Go to "Verifying the partition configuration" on page 189.