IBM BladeCenter JS12 Problem Determination And Service Manual page 59

Ibm power6 architecture
Table of Contents

Advertisement

Table 13. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
6909
6944
6950
6951
6952
6953
6954
6955
6956
6965
6970
6971
6972
Description
System bus error
Informational system log entry only.
A platform dump has occurred.
An error occurred because a partition
needed more NVRAM than was
available.
Informational system log entry only.
PHYP NVRAM is unavailable after a
service processor reset and reload.
Informational system log entry only.
Informational system log entry only.
An NVRAM failure was detected.
Informational system log entry only.
PCI host bridge failure
PCI bus failure
System bus error
Action
1. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
2. Go to "Isolating firmware problems" on
page 222.
No corrective action is required.
1. Collect the platform dump information.
2. Go to "Isolating firmware problems" on
page 222.
Use the Integrated Virtualization Manager
(IVM) to delete one or more partitions.
No corrective action is required.
Go to "Isolating firmware problems" on page
222.
No corrective action is required.
No corrective action is required.
Go to "Isolating firmware problems" on page
222.
No corrective action is required.
1. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
2.
If the problem persists, use the "PCI
expansion card (PIOCARD) problem
isolation procedure" on page 200 to
determine the failing component.
1. Use the "PCI expansion card (PIOCARD)
problem isolation procedure" on page 200
to determine the failing component.
2. If the problem persists, replace the
system-board and chassis assembly, as
described in "Replacing the Tier 2
system-board and chassis assembly" on
page 274.
Replace the system-board and chassis
assembly, as described in "Replacing the Tier 2
system-board and chassis assembly" on page
274.