IBM BladeCenter JS12 Problem Determination And Service Manual page 221

Ibm power6 architecture
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Isolation
Symptom
Procedure Code
FSPSP01
A part vital to system
function has been
deconfigured. Review
the system error logs
for errors that call out
CRUs that are
relevant to each
reason code.
Action
If replacing parts does not resolve the error, perform one of the
following procedures, based on the SRC code that is called out after the
FSPSP01 call.
If the SRC is B1xxB10C or B1xxB10D
The system has detected a deconfigured memory controller that is
required for the system to function, or it has detected that there is not
enough memory or that the memory is plugged incorrectly.
1. Reseat all of the memory DIMMs in the system enclosure but do not
replace any memory DIMMs at this time. Reseat the memory DIMMs
as described in "Installing a memory module" on page 251.
2. If the problem persists, replace each memory DIMM, by following
the action for symbolic FRU MEMDIMM.
3. Install the blade server into the BladeCenter unit after each DIMM
replacement and restart the blade to verify if the problem is solved.
4. If the problem persists after replacing all DIMMs, replace the system
board and chassis assembly, as described in "Replacing the Tier 2
system-board and chassis assembly" on page 274.
If the SRC is B1xxB107 or B1xxB108
The system has detected a problem with a clock card.
1. Replace the system board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on page
274.
If the SRC is B1xxB106
The system has detected that the planars are deconfigured.
1. Replace the system board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on page
274.
If the SRC is B1xxB110 or B1xxB111
The system has detected that all of the I/O bridges are deconfigured.
1. Replace the system board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on page
274.
207
Chapter 2. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents