Table 14. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
Error code
BA170211
BA170220
BA170221
BA170998
BA180008
BA180009
76
JS12 Type 7998: Problem Determination and Service Guide
Description
Setenv/$Setenv parameter error - value
contains a null character
Unable to write a variable value to
NVRAM due to lack of free memory in
NVRAM.
Setenv/$setenv had to delete stored
firmware network boot settings to free
memory in NVRAM.
NVRAMRC script evaluation error -
command line execution error.
PCI device Fcode evaluation error
The Fcode on a PCI adapter left a data
stack imbalance
Action
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
1. Reduce the number of partitions, if
possible, to add more NVRAM memory to
this partition.
2. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.
Enter the adapter and network parameters
again for the network boot or network
installation.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis assembly"
on page 274.
1. Reseat the PCI adapter card.
2. Check for adapter firmware updates; then,
install the updates if available.
3. Check for server firmware updates; then,
install the updates if available.
4. Replace the PCI adapter card.
5. If the problem persists:
a. Go to "Checkout procedure" on page
186.
b. Replace the system-board and chassis
assembly, as described in "Replacing the
Tier 2 system-board and chassis
assembly" on page 274.

Advertisement